{"product_id":"yaskawa-d1000-power-regenerative-converter-energy-saving-unit","title":"YASKAWA D1000 Power Regenerative Converter (200 V class, 5-130 kW)","description":"\u003cp class=\"ps-intro\"\u003eYASKAWA D1000 200 V class power regenerative converter (energy-saving unit) returning drive regenerative energy to the mains with near-unity power factor and low harmonics.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eReturns regenerative energy from drives and servo systems to the power supply instead of dissipating it\u003c\/li\u003e\n\u003cli\u003eSine-wave PWM control with input power factor of 0.99 min. at rated operation and very low harmonics\u003c\/li\u003e\n\u003cli\u003eSupplies a stable DC bus to one or more drives regardless of AC input voltage fluctuation\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block with parameter backup; MEMOBUS\/Modbus RS-422\/485 standard, option card slots\u003c\/li\u003e\n\u003cli\u003eMTO = made to order. Full model = CIMR-DA + voltage + A + capacity + enclosure (A IP00 \/ B IP20) + environment + revision; environmental versions K (gas), M (humidity\/dust), N (oil), S (vibration) on request; region A (Japan) and T (Asia) codes listed\u003c\/li\u003e\n\u003cli\u003eRequires the standard configuration devices (harmonic filter module and input AC reactor 1; 270-630 kW: reactors 1\/2, harmonic filter reactor and capacitor)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eD1000 Energy-Saving Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage class\u003c\/th\u003e\n\u003ctd\u003e200 V (3-phase 200-240 Vac, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity range\u003c\/th\u003e\n\u003ctd\u003e5 to 130 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated output voltage\u003c\/th\u003e\n\u003ctd\u003e330 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003ctd\u003eSine-wave PWM control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power factor\u003c\/th\u003e\n\u003ctd\u003e0.99 min. (rated operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload\u003c\/th\u003e\n\u003ctd\u003e150% 60 s \/ 200% 3 s of rated input current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, IEC61800-5-1, IEC61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00 \/ IP20 open-chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eYASKAWA D1000 catalogue, p. 8-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0005\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: B (IP20) | Capacity: 5 kW | Motor: 3.7 kW | Current: 15 A DC \/ 15 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0005BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis | Capacity: 5 kW | Motor: 3.7 kW | Current: 15 A DC \/ 15 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0010\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: B (IP20) | Capacity: 10 kW | Motor: 7.5 kW | Current: 30 A DC \/ 29 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0010BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis | Capacity: 10 kW | Motor: 7.5 kW | Current: 30 A DC \/ 29 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0020\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: B (IP20) | Capacity: 20 kW | Motor: 15 kW | Current: 61 A DC \/ 57 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0020BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis | Capacity: 20 kW | Motor: 15 kW | Current: 61 A DC \/ 57 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0030\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0030AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0030BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis (MTO) | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0050\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0050AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0050BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis (MTO) | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0065\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0065AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0065BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis (MTO) | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0090\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0090AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0090BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis (MTO) | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0130\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0130AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DA2A0130BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20 open-chassis (MTO) | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0005\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: B (IP20) | Capacity: 5 kW | Motor: 3.7 kW | Current: 15 A DC \/ 15 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0005BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis | Capacity: 5 kW | Motor: 3.7 kW | Current: 15 A DC \/ 15 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0010\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: B (IP20) | Capacity: 10 kW | Motor: 7.5 kW | Current: 30 A DC \/ 29 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0010BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis | Capacity: 10 kW | Motor: 7.5 kW | Current: 30 A DC \/ 29 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0020\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: B (IP20) | Capacity: 20 kW | Motor: 15 kW | Current: 61 A DC \/ 57 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0020BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis | Capacity: 20 kW | Motor: 15 kW | Current: 61 A DC \/ 57 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0030\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0030AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP00 open-chassis | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0030BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis (MTO) | Capacity: 30 kW | Motor: 22 kW | Current: 91 A DC \/ 83 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0050\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0050AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP00 open-chassis | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0050BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis (MTO) | Capacity: 50 kW | Motor: 37 kW | Current: 152 A DC \/ 140 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0065\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0065AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP00 open-chassis | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0065BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis (MTO) | Capacity: 65 kW | Motor: 55 kW | Current: 197 A DC \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0090\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0090AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP00 open-chassis | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0090BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis (MTO) | Capacity: 90 kW | Motor: 75 kW | Current: 273 A DC \/ 270 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0130\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: T (Asia) | Enclosure: A (IP00), B (IP20, MTO) | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0130AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP00 open-chassis | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-DT2A0130BAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: T (Asia) | Enclosure: IP20 open-chassis (MTO) | Capacity: 130 kW | Motor: 110 kW | Current: 394 A DC \/ 400 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"YASKAWA","offers":[{"title":"Default Title","offer_id":67517640573218,"sku":"CIMR-DA2A0005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/yaskawa-d1000-power-regenerative-converter-energy-saving-unit-1.jpg?v=1791888972","url":"https:\/\/prosourcemro.com\/products\/yaskawa-d1000-power-regenerative-converter-energy-saving-unit","provider":"ProSource MRO","version":"1.0","type":"link"}