{"product_id":"yaskawa-r1000-power-regenerative-unit-400-v-class","title":"YASKAWA R1000 Power Regenerative Unit (400 V class, 3.5-300 kW)","description":"\u003cp class=\"ps-intro\"\u003eYASKAWA R1000 400 V class power regenerative unit (energy-saving unit) that feeds drive regenerative energy back to the power supply.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eReturns regenerative energy from the connected drive to the power supply, replacing braking resistors\u003c\/li\u003e\n\u003cli\u003e120-degree excitation method; regenerative torque 150% 30 s, 100% 25% ED, 80% continuous\u003c\/li\u003e\n\u003cli\u003eInput power factor 0.9 min. at rated load; overload 150% of rated power supply current for 30 s\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block with parameter backup; MEMOBUS\/Modbus RS-422\/485 standard, option card slots\u003c\/li\u003e\n\u003cli\u003eMTO = made to order. Full model = CIMR-RA + voltage + A + capacity + enclosure (A IP00 \/ F IP20\/UL Type 1) + environment + revision; environmental versions K (gas), M (humidity\/dust), S (vibration) on request\u003c\/li\u003e\n\u003cli\u003eRequires the standard configuration devices: power coordinating reactor, current suppression reactor and input fuses\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eR1000 Energy-Saving Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage class\u003c\/th\u003e\n\u003ctd\u003e400 V (3-phase 380-480 Vac, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegeneration capacity\u003c\/th\u003e\n\u003ctd\u003e3.5 to 300 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003ctd\u003e120-degree excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput power factor\u003c\/th\u003e\n\u003ctd\u003e0.9 min. (rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload\u003c\/th\u003e\n\u003ctd\u003e150% of rated current for 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, IEC\/EN61800-5-1, IEC\/EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00 open-chassis \/ IP20 UL Type 1 panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eYASKAWA R1000 catalogue, p. 8-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A03P5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 3.5 kW | Motor: 3.7 kW | Current: 7 A DC \/ 5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A03P5FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 3.5 kW | Motor: 3.7 kW | Current: 7 A DC \/ 5 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0005\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 5 kW | Motor: 5.5 kW | Current: 11 A DC \/ 8 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0005FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 5 kW | Motor: 5.5 kW | Current: 11 A DC \/ 8 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0007\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 7 kW | Motor: 7.5 kW | Current: 15 A DC \/ 11 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0007FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 7 kW | Motor: 7.5 kW | Current: 15 A DC \/ 11 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0010\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 10 kW | Motor: 11 kW | Current: 22 A DC \/ 16 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0010FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 10 kW | Motor: 11 kW | Current: 22 A DC \/ 16 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0014\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 14 kW | Motor: 15 kW | Current: 30 A DC \/ 22 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0014FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 14 kW | Motor: 15 kW | Current: 30 A DC \/ 22 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0017\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 17 kW | Motor: 18.5 kW | Current: 36 A DC \/ 27 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0017FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 17 kW | Motor: 18.5 kW | Current: 36 A DC \/ 27 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0020\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 20 kW | Motor: 22 kW | Current: 43 A DC \/ 32 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0020FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 20 kW | Motor: 22 kW | Current: 43 A DC \/ 32 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0028\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: F (IP20\/UL Type 1) | Regen: 28 kW | Motor: 30 kW | Current: 58 A DC \/ 43 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0028FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure | Regen: 28 kW | Motor: 30 kW | Current: 58 A DC \/ 43 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0035\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 35 kW | Motor: 37 kW | Current: 73 A DC \/ 54 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0035AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 35 kW | Motor: 37 kW | Current: 73 A DC \/ 54 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0035FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 35 kW | Motor: 37 kW | Current: 73 A DC \/ 54 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0043\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 43 kW | Motor: 45 kW | Current: 89 A DC \/ 66 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0043AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 43 kW | Motor: 45 kW | Current: 89 A DC \/ 66 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0043FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 43 kW | Motor: 45 kW | Current: 89 A DC \/ 66 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0053\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 53 kW | Motor: 55 kW | Current: 109 A DC \/ 81 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0053AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 53 kW | Motor: 55 kW | Current: 109 A DC \/ 81 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0053FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 53 kW | Motor: 55 kW | Current: 109 A DC \/ 81 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0073\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 73 kW | Motor: 75 kW | Current: 149 A DC \/ 110 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0073AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 73 kW | Motor: 75 kW | Current: 149 A DC \/ 110 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0073FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 73 kW | Motor: 75 kW | Current: 149 A DC \/ 110 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0105\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 105 kW | Motor: 110 kW | Current: 217 A DC \/ 161 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0105AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 105 kW | Motor: 110 kW | Current: 217 A DC \/ 161 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0105FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 105 kW | Motor: 110 kW | Current: 217 A DC \/ 161 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00), F (IP20\/UL Type 1, MTO) | Regen: 150 kW | Motor: 160 kW | Current: 320 A DC \/ 237 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0150AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 150 kW | Motor: 160 kW | Current: 320 A DC \/ 237 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0150FAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP20\/UL Type 1 enclosure (MTO) | Regen: 150 kW | Motor: 160 kW | Current: 320 A DC \/ 237 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0210\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00) | Regen: 210 kW | Motor: 220 kW | Current: 440 A DC \/ 326 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0210AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 210 kW | Motor: 220 kW | Current: 440 A DC \/ 326 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0300\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model (specify enclosure) | Region: A (Japan) | Enclosure: A (IP00) | Regen: 300 kW | Motor: 315 kW | Current: 629 A DC \/ 466 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIMR-RA4A0300AAA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRegion: A (Japan) | Enclosure: IP00 open-chassis | Regen: 300 kW | Motor: 315 kW | Current: 629 A DC \/ 466 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"YASKAWA","offers":[{"title":"Default Title","offer_id":67535905849634,"sku":"CIMR-RA4A03P5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/yaskawa-r1000-power-regenerative-unit-energy-saving-unit-1.jpg?v=1791888972","url":"https:\/\/prosourcemro.com\/products\/yaskawa-r1000-power-regenerative-unit-400-v-class","provider":"ProSource MRO","version":"1.0","type":"link"}