{"product_id":"yaskawa-sglfw2-core-linear-servo-motors","title":"YASKAWA SGLFW2 F-type Iron-Core Linear Servo Motor Coils (Sigma-X)","description":"\u003cp class=\"ps-intro\"\u003eLinear Sigma SGLFW2 F-type iron-core moving coils (Sigma-X model numbers) for use with SGLFM2 magnet tracks and Sigma-X SERVOPACKs, delivering high force density in a flat single-sided design.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eIron-core coil on a single-sided flat magnet track; magnetic attraction can be used to preload bearings\u003c\/li\u003e\n\u003cli\u003eMagnet heights 30, 45, 90 and 135 mm (1D); rated force 45 N to 2520 N, peak force up to 7560 N\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal protector on all coils; S models add a Hall (magnetic pole) sensor\u003c\/li\u003e\n\u003cli\u003eMain-circuit lead 300 mm or 500 mm, with Tyco Electronics connector or bare lead ends\u003c\/li\u003e\n\u003cli\u003eWater-cooled (L) versions for 90A\/1DA coils available on request (not listed)\u003c\/li\u003e\n\u003cli\u003eCombine with SGLFM2 magnet tracks (270 - 714 mm lengths, combinable for longer strokes)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eLinear Sigma SGLFW2 (F-type core)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e200 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eNatural (self) cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax speed\u003c\/th\u003e\n\u003ctd\u003e2.5 - 5.0 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation class\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient\u003c\/th\u003e\n\u003ctd\u003e0 - 40 C, 20 - 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible drives\u003c\/th\u003e\n\u003ctd\u003eSigma-X SGDXS \/ SGDXW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eYASKAWA Sigma-X Catalog (Korean ed.), p. 314-339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A070AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 45 \/ 135 N | Rated current: 1.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A120AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 90 \/ 270 N | Rated current: 1.5 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-30A230AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 170-180 \/ 500-540 N | Rated current: 2.8-2.9 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A200AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 280 \/ 840 N | Rated current: 4.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-45A380AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1500-1680 N | Rated current: 8.7 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A200AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 560 \/ 1680 N | Rated current: 7.2 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A380AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1120 \/ 3360 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-90A560AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA380AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 1680 \/ 5040 N | Rated current: 14.4 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AS1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AS1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AS1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AS1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Hall sensor + thermal protector | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AT1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AT1F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: No connector, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AT1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: No connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSGLFW2-1DA560AT1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePart: Moving coil | Force (rated\/max): 2520 \/ 7560 N | Rated current: 21.6 Arms | Sensor: Thermal protector only | Lead: Tyco connector, 500 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"YASKAWA","offers":[{"title":"Default Title","offer_id":67535911518498,"sku":"SGLFW2-30A070AS1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/yaskawa-sglfw2-core-linear-servo-motors.jpg?v=1792161098","url":"https:\/\/prosourcemro.com\/products\/yaskawa-sglfw2-core-linear-servo-motors","provider":"ProSource MRO","version":"1.0","type":"link"}