{"product_id":"yuken-cjt70l-7mpa-hydraulic-cylinder-with-proximity-switch","title":"Yuken - CJT70L 7MPa Hydraulic Cylinder with Proximity Switch","description":"\u003cp class=\"ps-intro\"\u003eYUKEN CJT-series hydraulic cylinder with CE-compliant slide-type proximity switch.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eThe detection position is set freely and easily by adjusting the position of the slide-type proximity switch mounted on the cylinder body, eliminating the separate position-detection device on the machine and making the unit more compact\u003c\/li\u003e\n\u003cli\u003eThe proximity switch is available in lead-wire type (1.5 m standard \/ 5 m) and connector type\u003c\/li\u003e\n\u003cli\u003eBasic specifications are the same as the CJT70 (7 MPa standard) hydraulic cylinder\u003c\/li\u003e\n\u003cli\u003eConforms to former JIS B8354\u003c\/li\u003e\n\u003cli\u003eStroke is made-to-order - observe the minimum switch-mounting stroke\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eCJT70L (CE-compliant proximity-switch type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBase Series\u003c\/th\u003e\n\u003ctd\u003eCJT70 (7 MPa standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Pressure\u003c\/th\u003e\n\u003ctd\u003e7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign No.\u003c\/th\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStroke\u003c\/th\u003e\n\u003ctd\u003eMade-to-order (specify required stroke; min switch-mount stroke applies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch Min Stroke (Non-TC)\u003c\/th\u003e\n\u003ctd\u003e1 switch 20 mm \/ 2 switches 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupport (selectable)\u003c\/th\u003e\n\u003ctd\u003eSD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCushion\u003c\/th\u003e\n\u003ctd\u003eB: both ends \/ R: rod side \/ H: cap side \/ N: none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort Direction\u003c\/th\u003e\n\u003ctd\u003eA: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCushion Valve Direction\u003c\/th\u003e\n\u003ctd\u003eB: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir Bleed Direction\u003c\/th\u003e\n\u003ctd\u003eD: left (std) \/ A: top \/ B: right \/ C: bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003ctd\u003eF,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-32-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 32mm bore, B-rod d18mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 32 mm | Rod: B-series d18 mm | Design No.: 20 | Max Stroke: 1000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 110 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-32B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-32-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 32mm bore, C-rod d14mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 32 mm | Rod: C-series d14 mm | Design No.: 20 | Max Stroke: 1000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 110 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-32C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-40-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 40mm bore, A-rod d28mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 40 mm | Rod: A-series d28 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-40A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-40-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 40mm bore, B-rod d22mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 40 mm | Rod: B-series d22 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-40B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-40-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 40mm bore, C-rod d18mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 40 mm | Rod: C-series d18 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-40C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-50-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 50mm bore, A-rod d36mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 50 mm | Rod: A-series d36 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-50A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-50-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 50mm bore, B-rod d28mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 50 mm | Rod: B-series d28 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-50B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-50-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 50mm bore, C-rod d22mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 50 mm | Rod: C-series d22 mm | Design No.: 20 | Max Stroke: 1200 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 50 mm \/ 2 switches 115 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-50C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-63-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 63mm bore, A-rod d45mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 63 mm | Rod: A-series d45 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 125 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-63A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-63-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 63mm bore, B-rod d36mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 63 mm | Rod: B-series d36 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 125 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-63B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-63-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 63mm bore, C-rod d28mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 63 mm | Rod: C-series d28 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 125 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-63C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-80-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 80mm bore, A-rod d56mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 80 mm | Rod: A-series d56 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 130 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-80A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-80-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 80mm bore, B-rod d45mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 80 mm | Rod: B-series d45 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 130 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-80B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-80-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 80mm bore, C-rod d36mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 80 mm | Rod: C-series d36 mm | Design No.: 20 | Max Stroke: 1600 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 60 mm \/ 2 switches 130 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-80C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-100-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 100mm bore, A-rod d70mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 100 mm | Rod: A-series d70 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 65 mm \/ 2 switches 135 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-100A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-100-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 100mm bore, B-rod d56mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 100 mm | Rod: B-series d56 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 65 mm \/ 2 switches 135 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-100B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-100-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 100mm bore, C-rod d45mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 100 mm | Rod: C-series d45 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 65 mm \/ 2 switches 135 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-100C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-125-A-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 125mm bore, A-rod d90mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (A-rod) 15 MPa | Bore: 125 mm | Rod: A-series d90 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 70 mm \/ 2 switches 150 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-125A-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-125-B-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 125mm bore, B-rod d70mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (B-rod) 13.5 MPa | Bore: 125 mm | Rod: B-series d70 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 70 mm \/ 2 switches 150 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-125B-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJT70L-125-C-20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCJT70L 7MPa Hydraulic Cylinder w\/ proximity switch, 125mm bore, C-rod d56mm, design 20 | Series: CJT70L (CE-compliant proximity-switch type) | Base Series: CJT70 (7 MPa standard) | Nominal Pressure: 7 MPa | Max Allowable Pressure: Cap side 9 MPa \/ Rod side (C-rod) 11 MPa | Bore: 125 mm | Rod: C-series d56 mm | Design No.: 20 | Max Stroke: 2000 mm | Stroke: Made-to-order (specify required stroke; min switch-mount stroke applies) | Switch Min Stroke (Non-TC): 1 switch 20 mm \/ 2 switches 30 mm | Switch Min Stroke (TC, std trunnion pos): 1 switch 70 mm \/ 2 switches 150 mm | Proximity Switch: CE-compliant slide-type proximity switch; lead-wire type (1.5 m std \/ 5 m) or connector type; 1 or 2 switches (2+ switches: consult) | Support (selectable): SD, LA, LB, FA, FB, FC, FD, FE, FF, FY, CA, CB, TA, TC | Cushion: B: both ends \/ R: rod side \/ H: cap side \/ N: none | Port Direction: A: top (std) \/ B: right \/ C: bottom \/ D: left (viewed from rod side) | Cushion Valve Direction: B: right (std) \/ A: top \/ C: bottom \/ D: left \/ N: none | Air Bleed Direction: D: left (std) \/ A: top \/ B: right \/ C: bottom | Option: F,G,H: dust cover (nylon80\/CR130\/connex200) \/ K: lock nut \/ L: 1-piece rod-end \/ M: 2-piece rod-end | Packing: no symbol: NBR (std) \/ F: FKM \/ 6: HNBR | Max Speed: 300 mm\/s | Ambient Temp: -10 to +70 C | Standard: former JIS B8354 | Full Code: [F\/6]CJT70L-[support]-125C-[stroke]-[B\/R\/H\/N]-[port][valve][bleed]-[option]-[switch: lead\/connector, 1\/2pc, 1.5m\/5m]-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Yuken","offers":[{"title":"Default Title","offer_id":67396868866338,"sku":"YK-CJT70L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/002-163_81deea81-1a12-4f92-a9b8-d5953ce3a9d1.png?v=1790666914","url":"https:\/\/prosourcemro.com\/products\/yuken-cjt70l-7mpa-hydraulic-cylinder-with-proximity-switch","provider":"ProSource MRO","version":"1.0","type":"link"}