Miniature Circuit Breakers
LS ELECTRIC
[LS ELECTRIC] — BK63H Beyond X Miniature Circuit Breaker (HOUSE, IEC60898-1/IEC60947-2)
Family ID: LSE-BK63H-HOUSE
LS ELECTRIC Beyond X BK63H HOUSE family. | Application: Residential/commercial. | Frame: 63AF | Type: AC Miniature Circuit Breaker | Standard: IEC60898-1 / IEC60947-2 | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P / 4P | Breaking capacity: 10kA (Icu) | Ics: 75% Icu | Trip curve: B (4In) / C (7.5In) / D (12In) | Trip method: Thermal-Magnetic | Voltage: 240VAC (1P) / 415VAC (2~4P) | DC voltage: 60VDC (1P) / 125VDC (2~4P) | Uimp: 6kV | Ui: 500V | Mounting: 35mm DIN rail | Terminal: Lug/Screw dual | Endurance: 10,000 (electrical) / 20,000 (mechanical) | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS — see RFQ table for specific MPN.
156 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| BK63H B1/1P | BK63H B1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C1/1P | BK63H C1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D1/1P | BK63H D1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B2/1P | BK63H B2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C2/1P | BK63H C2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D2/1P | BK63H D2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B3/1P | BK63H B3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C3/1P | BK63H C3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D3/1P | BK63H D3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B4/1P | BK63H B4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C4/1P | BK63H C4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D4/1P | BK63H D4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B6/1P | BK63H B6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C6/1P | BK63H C6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D6/1P | BK63H D6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B10/1P | BK63H B10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C10/1P | BK63H C10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D10/1P | BK63H D10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B16/1P | BK63H B16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C16/1P | BK63H C16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D16/1P | BK63H D16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B20/1P | BK63H B20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C20/1P | BK63H C20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D20/1P | BK63H D20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B25/1P | BK63H B25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C25/1P | BK63H C25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D25/1P | BK63H D25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B32/1P | BK63H B32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C32/1P | BK63H C32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D32/1P | BK63H D32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B40/1P | BK63H B40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C40/1P | BK63H C40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D40/1P | BK63H D40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B50/1P | BK63H B50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C50/1P | BK63H C50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D50/1P | BK63H D50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B63/1P | BK63H B63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C63/1P | BK63H C63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D63/1P | BK63H D63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B1/2P | BK63H B1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C1/2P | BK63H C1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D1/2P | BK63H D1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B2/2P | BK63H B2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C2/2P | BK63H C2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D2/2P | BK63H D2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B3/2P | BK63H B3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C3/2P | BK63H C3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D3/2P | BK63H D3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B4/2P | BK63H B4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C4/2P | BK63H C4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D4/2P | BK63H D4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B6/2P | BK63H B6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C6/2P | BK63H C6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D6/2P | BK63H D6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B10/2P | BK63H B10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C10/2P | BK63H C10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D10/2P | BK63H D10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B16/2P | BK63H B16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C16/2P | BK63H C16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D16/2P | BK63H D16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B20/2P | BK63H B20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C20/2P | BK63H C20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D20/2P | BK63H D20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B25/2P | BK63H B25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C25/2P | BK63H C25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D25/2P | BK63H D25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B32/2P | BK63H B32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C32/2P | BK63H C32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D32/2P | BK63H D32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B40/2P | BK63H B40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C40/2P | BK63H C40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D40/2P | BK63H D40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B50/2P | BK63H B50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C50/2P | BK63H C50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D50/2P | BK63H D50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B63/2P | BK63H B63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C63/2P | BK63H C63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D63/2P | BK63H D63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B1/3P | BK63H B1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C1/3P | BK63H C1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D1/3P | BK63H D1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B2/3P | BK63H B2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C2/3P | BK63H C2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D2/3P | BK63H D2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B3/3P | BK63H B3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C3/3P | BK63H C3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D3/3P | BK63H D3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B4/3P | BK63H B4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C4/3P | BK63H C4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D4/3P | BK63H D4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B6/3P | BK63H B6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C6/3P | BK63H C6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D6/3P | BK63H D6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B10/3P | BK63H B10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C10/3P | BK63H C10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D10/3P | BK63H D10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B16/3P | BK63H B16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C16/3P | BK63H C16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D16/3P | BK63H D16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B20/3P | BK63H B20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C20/3P | BK63H C20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D20/3P | BK63H D20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B25/3P | BK63H B25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C25/3P | BK63H C25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D25/3P | BK63H D25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B32/3P | BK63H B32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C32/3P | BK63H C32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D32/3P | BK63H D32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B40/3P | BK63H B40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C40/3P | BK63H C40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D40/3P | BK63H D40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B50/3P | BK63H B50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C50/3P | BK63H C50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D50/3P | BK63H D50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B63/3P | BK63H B63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C63/3P | BK63H C63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D63/3P | BK63H D63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B1/4P | BK63H B1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C1/4P | BK63H C1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D1/4P | BK63H D1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B2/4P | BK63H B2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C2/4P | BK63H C2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D2/4P | BK63H D2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B3/4P | BK63H B3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C3/4P | BK63H C3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D3/4P | BK63H D3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B4/4P | BK63H B4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C4/4P | BK63H C4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D4/4P | BK63H D4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B6/4P | BK63H B6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C6/4P | BK63H C6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D6/4P | BK63H D6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B10/4P | BK63H B10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C10/4P | BK63H C10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D10/4P | BK63H D10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B16/4P | BK63H B16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C16/4P | BK63H C16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D16/4P | BK63H D16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B20/4P | BK63H B20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C20/4P | BK63H C20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D20/4P | BK63H D20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B25/4P | BK63H B25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C25/4P | BK63H C25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D25/4P | BK63H D25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B32/4P | BK63H B32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C32/4P | BK63H C32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D32/4P | BK63H D32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B40/4P | BK63H B40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C40/4P | BK63H C40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D40/4P | BK63H D40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B50/4P | BK63H B50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C50/4P | BK63H C50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D50/4P | BK63H D50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H B63/4P | BK63H B63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H C63/4P | BK63H C63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | ||
| BK63H D63/4P | BK63H D63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS |