[LS ELECTRIC] — Metasol MMS-32S Standard Manual Motor Starter (32AF, Sub-Amp 0.16~1A, 3-Pole, Toggle Handle)

[LS ELECTRIC] — Metasol MMS-32S Standard Manual Motor Starter (32AF, Sub-Amp 0.16~1A, 3-Pole, Toggle Handle)

Family ID: LSE-MMS-32S-SUBAMP

Metasol MMS-32S Manual Motor Starter — Sub-Amp (0.16~1A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Sub-amp range for control circuits, micro motors, instrumentation, and small valve actuators. Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508, K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.

10 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MMS-32S/0.16A Metasol MMS-32S 0.16A, Standard terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: 0.1~0.16A (±20% via dial) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.16A O-RING TERMINAL Metasol MMS-32S 0.16A, O-Ring Terminal terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: 0.1~0.16A (±20% via dial) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.25A Metasol MMS-32S 0.25A, Standard terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: 0.16~0.25A (±20% via dial) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.25A O-RING TERMINAL Metasol MMS-32S 0.25A, O-Ring Terminal terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: 0.16~0.25A (±20% via dial) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.4A Metasol MMS-32S 0.4A, Standard terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: 0.25~0.4A (±20% via dial) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.4A O-RING TERMINAL Metasol MMS-32S 0.4A, O-Ring Terminal terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: 0.25~0.4A (±20% via dial) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.63A Metasol MMS-32S 0.63A, Standard terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: 0.4~0.63A (±20% via dial) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/0.63A O-RING TERMINAL Metasol MMS-32S 0.63A, O-Ring Terminal terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: 0.4~0.63A (±20% via dial) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/1A Metasol MMS-32S 1A, Standard terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: 0.63~1A (±20% via dial) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/1A O-RING TERMINAL Metasol MMS-32S 1A, O-Ring Terminal terminal, Standard (Sub-Amp) LS ELECTRIC Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: 0.63~1A (±20% via dial) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC