[LS ELECTRIC] — Metasol MMS-63S Standard Manual Motor Starter (63AF, High Range 32~65A, 3-Pole, Rotary Handle)

[LS ELECTRIC] — Metasol MMS-63S Standard Manual Motor Starter (63AF, High Range 32~65A, 3-Pole, Rotary Handle)

Family ID: LSE-MMS-63S-HIGH

Metasol MMS-63S Manual Motor Starter — High Range (32~65A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (63AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. High range for motors 7.5~30kW (15kW @ 220V / 30kW @ 440V). Frame: 63AF, width 55mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.

10 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MMS-63S/32A Metasol MMS-63S 32A, Standard terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/32A O-RING TERMINAL Metasol MMS-63S 32A, O-Ring Terminal terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/40A Metasol MMS-63S 40A, Standard terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/40A O-RING TERMINAL Metasol MMS-63S 40A, O-Ring Terminal terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/50A Metasol MMS-63S 50A, Standard terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/50A O-RING TERMINAL Metasol MMS-63S 50A, O-Ring Terminal terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/63A Metasol MMS-63S 63A, Standard terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/63A O-RING TERMINAL Metasol MMS-63S 63A, O-Ring Terminal terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/65A Metasol MMS-63S 65A, Standard terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 65A | Adjustment Range: 47~65A (±20% via dial) | Instantaneous Trip: 845A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/65A O-RING TERMINAL Metasol MMS-63S 65A, O-Ring Terminal terminal, Standard (High Range) LS ELECTRIC Frame: 63AF | Capacity Band: High Range (32~65A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 65A | Adjustment Range: 47~65A (±20% via dial) | Instantaneous Trip: 845A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC