[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xN400KP Reversing Magnetic Starter (400A AC-3, N400 Frame, TH-N400RHKP 3-Element Thermal)
Magnetic Starters MITSUBISHI ELECTRIC

[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xN400KP Reversing Magnetic Starter (400A AC-3, N400 Frame, TH-N400RHKP 3-Element Thermal)

Family ID: MEL-MSTR-KP-2XN400

Mitsubishi Electric MS-T/N series N400-frame reversing open-type magnetic starter MSO-2xN400KP with TH-N400RHKP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching.

36 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSO-2xN400KP 105A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 105A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 105A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 105A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 105A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 105A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 105A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 125A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 125A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 150A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 150A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 180A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 180A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 250A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 250A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC48V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC48V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC100V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC100V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC200V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC200V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC300V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC300V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC400V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC400V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xN400KP 330A AC500V MSO-2xN400KP reversing starter with 2E thermal, N400 frame, 330A heater, AC500V coil Mitsubishi Electric Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RHKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4