Magnetic Starters
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xT20 Reversing Magnetic Starter (18A AC-3, T20 Frame, TH-T18 Thermal)
Family ID: MEL-MSTR-2XT20
Mitsubishi Electric MS-T/N series T20-frame reversing open-type magnetic starter MSO-2xT20: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
119 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MSO-2xT20 0.12A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.12A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.17A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.24A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.35A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.5A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.7A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC24V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC48V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC100V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC200V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC300V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC400V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 0.9A AC500V | MSO-2xT20 reversing starter, T20 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC24V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC48V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC100V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC200V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC300V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC400V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.3A AC500V | MSO-2xT20 reversing starter, T20 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC24V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC48V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC100V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC200V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC300V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC400V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 1.7A AC500V | MSO-2xT20 reversing starter, T20 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC24V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC48V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC100V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC200V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC300V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC400V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.1A AC500V | MSO-2xT20 reversing starter, T20 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC24V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC48V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC100V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC200V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC300V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC400V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 2.5A AC500V | MSO-2xT20 reversing starter, T20 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC24V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC48V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC100V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC200V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC300V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC400V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 3.6A AC500V | MSO-2xT20 reversing starter, T20 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC24V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC48V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC100V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC200V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC300V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC400V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 5A AC500V | MSO-2xT20 reversing starter, T20 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC24V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC48V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC100V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC200V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC300V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC400V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 6.6A AC500V | MSO-2xT20 reversing starter, T20 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC24V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC48V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC100V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC200V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC300V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC400V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 9A AC500V | MSO-2xT20 reversing starter, T20 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC24V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC48V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC100V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC200V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC300V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC400V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 11A AC500V | MSO-2xT20 reversing starter, T20 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC24V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC48V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC100V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC200V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC300V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC400V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-2xT20 15A AC500V | MSO-2xT20 reversing starter, T20 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |