| Product code | Spec | ||
|---|---|---|---|
| IPX-D12-02E1 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E1N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E1 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E1N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E1 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E1N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 15.0 mm | ||
| IPX-D12-02E1R | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E1RN | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E1R | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E1RN | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E1R | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E1RN | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 15.0 mm | ||
| IPX-D12-02E1W | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E1WN | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E1W | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E1WN | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E1W | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Shielded | Output: NPN NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E1WN | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NO | Sensing distance: 15.0 mm | ||
| IPX-D17-05E1S | Shape: Rectangular | Connection: Cable (2 m) | Size: 17 mm square | Shield: Not specified | Output: NPN NO | Sensing distance: 5.0 mm | ||
| IPX-D25-05E1S | Shape: Rectangular | Connection: Cable (2 m) | Size: 25 mm square | Shield: Not specified | Output: NPN NO | Sensing distance: 5.0 mm | ||
| IPX-D30-10E1S | Shape: Rectangular | Connection: Cable (2 m) | Size: 30 mm square | Shield: Not specified | Output: NPN NO | Sensing distance: 10.0 mm | ||
| IPX-D40-20E1S | Shape: Rectangular | Connection: Cable (2 m) | Size: 40 mm square | Shield: Not specified | Output: NPN NO | Sensing distance: 20.0 mm | ||
| IPX-D12-02E2 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E2N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E2 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E2N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E2 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E2N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 15.0 mm | ||
| IPX-D12-02E2R | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E2RN | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E2R | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E2RN | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E2R | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E2RN | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 15.0 mm | ||
| IPX-D12-02E2W | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E2WN | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E2W | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E2WN | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E2W | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Shielded | Output: NPN NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E2WN | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Unshielded | Output: NPN NC | Sensing distance: 15.0 mm | ||
| IPX-D17-05E2S | Shape: Rectangular | Connection: Cable (2 m) | Size: 17 mm square | Shield: Not specified | Output: NPN NC | Sensing distance: 5.0 mm | ||
| IPX-D25-05E2S | Shape: Rectangular | Connection: Cable (2 m) | Size: 25 mm square | Shield: Not specified | Output: NPN NC | Sensing distance: 5.0 mm | ||
| IPX-D30-10E2S | Shape: Rectangular | Connection: Cable (2 m) | Size: 30 mm square | Shield: Not specified | Output: NPN NC | Sensing distance: 10.0 mm | ||
| IPX-D40-20E2S | Shape: Rectangular | Connection: Cable (2 m) | Size: 40 mm square | Shield: Not specified | Output: NPN NC | Sensing distance: 20.0 mm | ||
| IPX-D12-02E3 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E3N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E3 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E3N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E3 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E3N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 15.0 mm | ||
| IPX-D12-02E3R | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E3RN | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E3R | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E3RN | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E3R | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E3RN | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 15.0 mm | ||
| IPX-D12-02E3W | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 2.0 mm | ||
| IPX-D12-04E3WN | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 4.0 mm | ||
| IPX-D18-05E3W | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 5.0 mm | ||
| IPX-D18-08E3WN | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 8.0 mm | ||
| IPX-D30-10E3W | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Shielded | Output: PNP NO | Sensing distance: 10.0 mm | ||
| IPX-D30-15E3WN | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NO | Sensing distance: 15.0 mm | ||
| IPX-D17-05E3S | Shape: Rectangular | Connection: Cable (2 m) | Size: 17 mm square | Shield: Not specified | Output: PNP NO | Sensing distance: 5.0 mm | ||
| IPX-D25-05E3S | Shape: Rectangular | Connection: Cable (2 m) | Size: 25 mm square | Shield: Not specified | Output: PNP NO | Sensing distance: 5.0 mm | ||
| IPX-D30-10E3S | Shape: Rectangular | Connection: Cable (2 m) | Size: 30 mm square | Shield: Not specified | Output: PNP NO | Sensing distance: 10.0 mm | ||
| IPX-D40-20E3S | Shape: Rectangular | Connection: Cable (2 m) | Size: 40 mm square | Shield: Not specified | Output: PNP NO | Sensing distance: 20.0 mm | ||
| IPX-D12-02E4 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E4N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E4 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E4N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E4 | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E4N | Shape: Cylindrical | Connection: Cable (2 m) | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 15.0 mm | ||
| IPX-D12-02E4R | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E4RN | Shape: Cylindrical | Connection: M12 connector | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E4R | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E4RN | Shape: Cylindrical | Connection: M12 connector | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E4R | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E4RN | Shape: Cylindrical | Connection: M12 connector | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 15.0 mm | ||
| IPX-D12-02E4W | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 2.0 mm | ||
| IPX-D12-04E4WN | Shape: Cylindrical | Connection: Wire connector | Size: 12 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 4.0 mm | ||
| IPX-D18-05E4W | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 5.0 mm | ||
| IPX-D18-08E4WN | Shape: Cylindrical | Connection: Wire connector | Size: 18 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 8.0 mm | ||
| IPX-D30-10E4W | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Shielded | Output: PNP NC | Sensing distance: 10.0 mm | ||
| IPX-D30-15E4WN | Shape: Cylindrical | Connection: Wire connector | Size: 30 mm dia. | Shield: Unshielded | Output: PNP NC | Sensing distance: 15.0 mm | ||
| IPX-D17-05E4S | Shape: Rectangular | Connection: Cable (2 m) | Size: 17 mm square | Shield: Not specified | Output: PNP NC | Sensing distance: 5.0 mm | ||
| IPX-D25-05E4S | Shape: Rectangular | Connection: Cable (2 m) | Size: 25 mm square | Shield: Not specified | Output: PNP NC | Sensing distance: 5.0 mm | ||
| IPX-D30-10E4S | Shape: Rectangular | Connection: Cable (2 m) | Size: 30 mm square | Shield: Not specified | Output: PNP NC | Sensing distance: 10.0 mm | ||
| IPX-D40-20E4S | Shape: Rectangular | Connection: Cable (2 m) | Size: 40 mm square | Shield: Not specified | Output: PNP NC | Sensing distance: 20.0 mm |
Need a different model, or a part not listed here? Send us your parts list →