[LS ELECTRIC] — EBS50-A Metasol ELCB (S-type (Standard breaking capacity), 18kA @ 415V, A Type, 15~50A)

[LS ELECTRIC] — EBS50-A Metasol ELCB (S-type (Standard breaking capacity), 18kA @ 415V, A Type, 15~50A)

Family ID: LSE-EBS50-A

LS ELECTRIC Metasol ELCB EBS50-A family. Frame: 50AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 16 variants — see RFQ table for specific MPN.

16 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
EBS53c/15A-A-TYPE Metasol ELCB EBS50-A — 15A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/15A-A-TYPE Metasol ELCB EBS50-A — 15A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/16A-A-TYPE Metasol ELCB EBS50-A — 16A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/16A-A-TYPE Metasol ELCB EBS50-A — 16A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/20A-A-TYPE Metasol ELCB EBS50-A — 20A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/20A-A-TYPE Metasol ELCB EBS50-A — 20A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/25A-A-TYPE Metasol ELCB EBS50-A — 25A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/25A-A-TYPE Metasol ELCB EBS50-A — 25A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/30A-A-TYPE Metasol ELCB EBS50-A — 30A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/30A-A-TYPE Metasol ELCB EBS50-A — 30A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/32A-A-TYPE Metasol ELCB EBS50-A — 32A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/32A-A-TYPE Metasol ELCB EBS50-A — 32A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/40A-A-TYPE Metasol ELCB EBS50-A — 40A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/40A-A-TYPE Metasol ELCB EBS50-A — 40A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS53c/50A-A-TYPE Metasol ELCB EBS50-A — 50A 3P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBS54c/50A-A-TYPE Metasol ELCB EBS50-A — 50A 4P, A Type LS ELECTRIC Frame: 50AF | Type: S-type (Standard breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers