LS ELECTRIC Metasol ELCB EBH125-A family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 28 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH125-A family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 28 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH103c/15A-A-TYPE | Metasol ELCB EBH125-A — 15A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/15A-A-TYPE | Metasol ELCB EBH125-A — 15A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/16A-A-TYPE | Metasol ELCB EBH125-A — 16A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/16A-A-TYPE | Metasol ELCB EBH125-A — 16A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/20A-A-TYPE | Metasol ELCB EBH125-A — 20A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/20A-A-TYPE | Metasol ELCB EBH125-A — 20A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/25A-A-TYPE | Metasol ELCB EBH125-A — 25A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/25A-A-TYPE | Metasol ELCB EBH125-A — 25A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/30A-A-TYPE | Metasol ELCB EBH125-A — 30A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/30A-A-TYPE | Metasol ELCB EBH125-A — 30A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/32A-A-TYPE | Metasol ELCB EBH125-A — 32A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/32A-A-TYPE | Metasol ELCB EBH125-A — 32A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/40A-A-TYPE | Metasol ELCB EBH125-A — 40A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/40A-A-TYPE | Metasol ELCB EBH125-A — 40A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/50A-A-TYPE | Metasol ELCB EBH125-A — 50A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/50A-A-TYPE | Metasol ELCB EBH125-A — 50A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/60A-A-TYPE | Metasol ELCB EBH125-A — 60A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/60A-A-TYPE | Metasol ELCB EBH125-A — 60A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/63A-A-TYPE | Metasol ELCB EBH125-A — 63A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/63A-A-TYPE | Metasol ELCB EBH125-A — 63A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/75A-A-TYPE | Metasol ELCB EBH125-A — 75A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/75A-A-TYPE | Metasol ELCB EBH125-A — 75A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/80A-A-TYPE | Metasol ELCB EBH125-A — 80A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/80A-A-TYPE | Metasol ELCB EBH125-A — 80A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/100A-A-TYPE | Metasol ELCB EBH125-A — 100A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/100A-A-TYPE | Metasol ELCB EBH125-A — 100A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/125A-A-TYPE | Metasol ELCB EBH125-A — 125A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/125A-A-TYPE | Metasol ELCB EBH125-A — 125A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBH125-AC family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 28 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH125-AC family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 28 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH103c/15A | Metasol ELCB EBH125-AC — 15A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/15A | Metasol ELCB EBH125-AC — 15A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/16A | Metasol ELCB EBH125-AC — 16A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/16A | Metasol ELCB EBH125-AC — 16A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/20A | Metasol ELCB EBH125-AC — 20A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/20A | Metasol ELCB EBH125-AC — 20A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/25A | Metasol ELCB EBH125-AC — 25A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/25A | Metasol ELCB EBH125-AC — 25A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/30A | Metasol ELCB EBH125-AC — 30A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/30A | Metasol ELCB EBH125-AC — 30A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/32A | Metasol ELCB EBH125-AC — 32A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/32A | Metasol ELCB EBH125-AC — 32A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/40A | Metasol ELCB EBH125-AC — 40A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/40A | Metasol ELCB EBH125-AC — 40A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/50A | Metasol ELCB EBH125-AC — 50A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/50A | Metasol ELCB EBH125-AC — 50A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/60A | Metasol ELCB EBH125-AC — 60A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/60A | Metasol ELCB EBH125-AC — 60A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/63A | Metasol ELCB EBH125-AC — 63A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/63A | Metasol ELCB EBH125-AC — 63A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/75A | Metasol ELCB EBH125-AC — 75A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/75A | Metasol ELCB EBH125-AC — 75A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/80A | Metasol ELCB EBH125-AC — 80A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/80A | Metasol ELCB EBH125-AC — 80A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/100A | Metasol ELCB EBH125-AC — 100A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/100A | Metasol ELCB EBH125-AC — 100A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH103c/125A | Metasol ELCB EBH125-AC — 125A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH104c/125A | Metasol ELCB EBH125-AC — 125A 4P, AC Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBH250-A family. Frame: 250AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH250-A family. Frame: 250AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH203c/100A-A-TYPE | Metasol ELCB EBH250-A — 100A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/100A-A-TYPE | Metasol ELCB EBH250-A — 100A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/125A-A-TYPE | Metasol ELCB EBH250-A — 125A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/125A-A-TYPE | Metasol ELCB EBH250-A — 125A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/150A-A-TYPE | Metasol ELCB EBH250-A — 150A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 150A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/150A-A-TYPE | Metasol ELCB EBH250-A — 150A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 150A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/160A-A-TYPE | Metasol ELCB EBH250-A — 160A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/160A-A-TYPE | Metasol ELCB EBH250-A — 160A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/175A-A-TYPE | Metasol ELCB EBH250-A — 175A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 175A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/175A-A-TYPE | Metasol ELCB EBH250-A — 175A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 175A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/200A-A-TYPE | Metasol ELCB EBH250-A — 200A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/200A-A-TYPE | Metasol ELCB EBH250-A — 200A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/225A-A-TYPE | Metasol ELCB EBH250-A — 225A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 225A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/225A-A-TYPE | Metasol ELCB EBH250-A — 225A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 225A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH203c/250A-A-TYPE | Metasol ELCB EBH250-A — 250A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH204c/250A-A-TYPE | Metasol ELCB EBH250-A — 250A 4P, A Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBH250-AC family. Frame: 250AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH250-AC family. Frame: 250AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH203c/100A | Metasol ELCB EBH250-AC — 100A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/100A | Metasol ELCB EBH250-AC — 100A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/125A | Metasol ELCB EBH250-AC — 125A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/125A | Metasol ELCB EBH250-AC — 125A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/150A | Metasol ELCB EBH250-AC — 150A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 150A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/150A | Metasol ELCB EBH250-AC — 150A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 150A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/160A | Metasol ELCB EBH250-AC — 160A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/160A | Metasol ELCB EBH250-AC — 160A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/175A | Metasol ELCB EBH250-AC — 175A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 175A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/175A | Metasol ELCB EBH250-AC — 175A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 175A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/200A | Metasol ELCB EBH250-AC — 200A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/200A | Metasol ELCB EBH250-AC — 200A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 200A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/225A | Metasol ELCB EBH250-AC — 225A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 225A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/225A | Metasol ELCB EBH250-AC — 225A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 225A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH203c/250A | Metasol ELCB EBH250-AC — 250A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH204c/250A | Metasol ELCB EBH250-AC — 250A 4P, AC Type | LS ELECTRIC | Frame: 250AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 140×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBH400-AC family. Frame: 400AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH400-AC family. Frame: 400AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH403c/250A | Metasol ELCB EBH400-AC — 250A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH404c/250A | Metasol ELCB EBH400-AC — 250A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH403c/300A | Metasol ELCB EBH400-AC — 300A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 300A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH404c/300A | Metasol ELCB EBH400-AC — 300A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 300A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH403c/350A | Metasol ELCB EBH400-AC — 350A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 350A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH404c/350A | Metasol ELCB EBH400-AC — 350A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 350A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH403c/400A | Metasol ELCB EBH400-AC — 400A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 400A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH404c/400A | Metasol ELCB EBH400-AC — 400A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: H-type (High breaking capacity) | Rated current (In): 400A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
[LS ELECTRIC] — EBH50-A Metasol ELCB (H-type (High breaking capacity), 50kA @ 415V, A Type, 15~50A)
▶LS ELECTRIC Metasol ELCB EBH50-A family. Frame: 50AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH50-A family. Frame: 50AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH53c/15A-A-TYPE | Metasol ELCB EBH50-A — 15A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/15A-A-TYPE | Metasol ELCB EBH50-A — 15A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/16A-A-TYPE | Metasol ELCB EBH50-A — 16A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/16A-A-TYPE | Metasol ELCB EBH50-A — 16A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/20A-A-TYPE | Metasol ELCB EBH50-A — 20A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/20A-A-TYPE | Metasol ELCB EBH50-A — 20A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/25A-A-TYPE | Metasol ELCB EBH50-A — 25A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/25A-A-TYPE | Metasol ELCB EBH50-A — 25A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/30A-A-TYPE | Metasol ELCB EBH50-A — 30A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/30A-A-TYPE | Metasol ELCB EBH50-A — 30A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/32A-A-TYPE | Metasol ELCB EBH50-A — 32A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/32A-A-TYPE | Metasol ELCB EBH50-A — 32A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/40A-A-TYPE | Metasol ELCB EBH50-A — 40A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/40A-A-TYPE | Metasol ELCB EBH50-A — 40A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH53c/50A-A-TYPE | Metasol ELCB EBH50-A — 50A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH54c/50A-A-TYPE | Metasol ELCB EBH50-A — 50A 4P, A Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBH50-AC family. Frame: 50AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH50-AC family. Frame: 50AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH53c/15A | Metasol ELCB EBH50-AC — 15A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/15A | Metasol ELCB EBH50-AC — 15A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/16A | Metasol ELCB EBH50-AC — 16A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/16A | Metasol ELCB EBH50-AC — 16A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/20A | Metasol ELCB EBH50-AC — 20A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/20A | Metasol ELCB EBH50-AC — 20A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/25A | Metasol ELCB EBH50-AC — 25A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/25A | Metasol ELCB EBH50-AC — 25A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/30A | Metasol ELCB EBH50-AC — 30A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/30A | Metasol ELCB EBH50-AC — 30A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/32A | Metasol ELCB EBH50-AC — 32A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/32A | Metasol ELCB EBH50-AC — 32A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/40A | Metasol ELCB EBH50-AC — 40A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/40A | Metasol ELCB EBH50-AC — 40A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH53c/50A | Metasol ELCB EBH50-AC — 50A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBH54c/50A | Metasol ELCB EBH50-AC — 50A 4P, AC Type | LS ELECTRIC | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBL400-AC family. Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBL400-AC family. Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBL403c/250A | Metasol ELCB EBL400-AC — 250A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL404c/250A | Metasol ELCB EBL400-AC — 250A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 250A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL403c/300A | Metasol ELCB EBL400-AC — 300A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 300A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL404c/300A | Metasol ELCB EBL400-AC — 300A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 300A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL403c/350A | Metasol ELCB EBL400-AC — 350A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 350A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL404c/350A | Metasol ELCB EBL400-AC — 350A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 350A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL403c/400A | Metasol ELCB EBL400-AC — 400A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 400A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL404c/400A | Metasol ELCB EBL400-AC — 400A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 400A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBL630-AC family. Frame: 630AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBL630-AC family. Frame: 630AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBL603c/500A | Metasol ELCB EBL630-AC — 500A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 500A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL603c/630A | Metasol ELCB EBL630-AC — 630A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 630A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBL800-AC family. Frame: 800AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 700A, 800A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBL800-AC family. Frame: 800AF | Type: L-type (Limited/Highest breaking capacity) | Breaking capacity Icu: 85kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 700A, 800A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBL803c/700A | Metasol ELCB EBL800-AC — 700A 3P, AC Type | LS ELECTRIC | Frame: 800AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 700A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBL803c/800A | Metasol ELCB EBL800-AC — 800A 3P, AC Type | LS ELECTRIC | Frame: 800AF | Type: L-type (Limited/Highest breaking capacity) | Rated current (In): 800A | Breaking capacity Icu: 85kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN125-A family. Frame: 125AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 14 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN125-A family. Frame: 125AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 14 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN103c/15A-A-TYPE | Metasol ELCB EBN125-A — 15A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 15A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/16A-A-TYPE | Metasol ELCB EBN125-A — 16A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 16A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/20A-A-TYPE | Metasol ELCB EBN125-A — 20A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 20A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/25A-A-TYPE | Metasol ELCB EBN125-A — 25A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 25A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/30A-A-TYPE | Metasol ELCB EBN125-A — 30A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 30A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/32A-A-TYPE | Metasol ELCB EBN125-A — 32A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 32A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/40A-A-TYPE | Metasol ELCB EBN125-A — 40A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 40A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/50A-A-TYPE | Metasol ELCB EBN125-A — 50A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 50A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/60A-A-TYPE | Metasol ELCB EBN125-A — 60A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/63A-A-TYPE | Metasol ELCB EBN125-A — 63A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 63A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/75A-A-TYPE | Metasol ELCB EBN125-A — 75A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 75A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/80A-A-TYPE | Metasol ELCB EBN125-A — 80A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 80A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/100A-A-TYPE | Metasol ELCB EBN125-A — 100A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 100A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN103c/125A-A-TYPE | Metasol ELCB EBN125-A — 125A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 125A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBN125-AC family. Frame: 125AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 14 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN125-AC family. Frame: 125AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 14 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN103c/15A | Metasol ELCB EBN125-AC — 15A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 15A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/16A | Metasol ELCB EBN125-AC — 16A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 16A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/20A | Metasol ELCB EBN125-AC — 20A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 20A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/25A | Metasol ELCB EBN125-AC — 25A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 25A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/30A | Metasol ELCB EBN125-AC — 30A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 30A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/32A | Metasol ELCB EBN125-AC — 32A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 32A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/40A | Metasol ELCB EBN125-AC — 40A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 40A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/50A | Metasol ELCB EBN125-AC — 50A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 50A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/60A | Metasol ELCB EBN125-AC — 60A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/63A | Metasol ELCB EBN125-AC — 63A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 63A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/75A | Metasol ELCB EBN125-AC — 75A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 75A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/80A | Metasol ELCB EBN125-AC — 80A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 80A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/100A | Metasol ELCB EBN125-AC — 100A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 100A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN103c/125A | Metasol ELCB EBN125-AC — 125A 3P, AC Type | LS ELECTRIC | Frame: 125AF | Type: N-type (Normal/Standard) | Rated current (In): 125A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN250-A family. Frame: 250AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 26kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN250-A family. Frame: 250AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 26kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN203c/100A-A-TYPE | Metasol ELCB EBN250-A — 100A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 100A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/125A-A-TYPE | Metasol ELCB EBN250-A — 125A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 125A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/150A-A-TYPE | Metasol ELCB EBN250-A — 150A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 150A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/160A-A-TYPE | Metasol ELCB EBN250-A — 160A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 160A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/175A-A-TYPE | Metasol ELCB EBN250-A — 175A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 175A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/200A-A-TYPE | Metasol ELCB EBN250-A — 200A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 200A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/225A-A-TYPE | Metasol ELCB EBN250-A — 225A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 225A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN203c/250A-A-TYPE | Metasol ELCB EBN250-A — 250A 3P, A Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 250A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBN250-AC family. Frame: 250AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 26kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN250-AC family. Frame: 250AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 26kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 100A, 125A, 150A, 160A, 175A, 200A, 225A, 250A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN203c/100A | Metasol ELCB EBN250-AC — 100A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 100A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/125A | Metasol ELCB EBN250-AC — 125A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 125A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/150A | Metasol ELCB EBN250-AC — 150A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 150A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/160A | Metasol ELCB EBN250-AC — 160A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 160A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/175A | Metasol ELCB EBN250-AC — 175A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 175A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/200A | Metasol ELCB EBN250-AC — 200A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 200A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/225A | Metasol ELCB EBN250-AC — 225A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 225A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN203c/250A | Metasol ELCB EBN250-AC — 250A 3P, AC Type | LS ELECTRIC | Frame: 250AF | Type: N-type (Normal/Standard) | Rated current (In): 250A | Breaking capacity Icu: 26kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 105×165×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN400-AC family. Frame: 400AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 37kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN400-AC family. Frame: 400AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 37kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 250A, 300A, 350A, 400A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN403c/250A | Metasol ELCB EBN400-AC — 250A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 250A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN404c/250A | Metasol ELCB EBN400-AC — 250A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 250A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN403c/300A | Metasol ELCB EBN400-AC — 300A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 300A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN404c/300A | Metasol ELCB EBN400-AC — 300A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 300A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN403c/350A | Metasol ELCB EBN400-AC — 350A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 350A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN404c/350A | Metasol ELCB EBN400-AC — 350A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 350A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN403c/400A | Metasol ELCB EBN400-AC — 400A 3P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 400A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 140×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN404c/400A | Metasol ELCB EBN400-AC — 400A 4P, AC Type | LS ELECTRIC | Frame: 400AF | Type: N-type (Normal/Standard) | Rated current (In): 400A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 184×257×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN50-A family. Frame: 50AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN50-A family. Frame: 50AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN53c/15A-A-TYPE | Metasol ELCB EBN50-A — 15A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 15A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/16A-A-TYPE | Metasol ELCB EBN50-A — 16A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 16A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/20A-A-TYPE | Metasol ELCB EBN50-A — 20A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 20A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/25A-A-TYPE | Metasol ELCB EBN50-A — 25A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 25A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/30A-A-TYPE | Metasol ELCB EBN50-A — 30A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 30A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/32A-A-TYPE | Metasol ELCB EBN50-A — 32A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 32A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/40A-A-TYPE | Metasol ELCB EBN50-A — 40A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 40A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBN53c/50A-A-TYPE | Metasol ELCB EBN50-A — 50A 3P, A Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 50A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBN50-AC family. Frame: 50AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 2P / 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN50-AC family. Frame: 50AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A | Pole: 2P / 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN52c/15A | Metasol ELCB EBN50-AC — 15A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 15A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/15A | Metasol ELCB EBN50-AC — 15A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 15A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/16A | Metasol ELCB EBN50-AC — 16A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 16A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/16A | Metasol ELCB EBN50-AC — 16A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 16A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/20A | Metasol ELCB EBN50-AC — 20A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 20A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/20A | Metasol ELCB EBN50-AC — 20A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 20A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/25A | Metasol ELCB EBN50-AC — 25A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 25A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/25A | Metasol ELCB EBN50-AC — 25A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 25A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/30A | Metasol ELCB EBN50-AC — 30A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 30A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/30A | Metasol ELCB EBN50-AC — 30A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 30A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/32A | Metasol ELCB EBN50-AC — 32A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 32A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/32A | Metasol ELCB EBN50-AC — 32A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 32A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/40A | Metasol ELCB EBN50-AC — 40A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 40A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/40A | Metasol ELCB EBN50-AC — 40A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 40A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN52c/50A | Metasol ELCB EBN50-AC — 50A 2P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 50A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 2P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN53c/50A | Metasol ELCB EBN50-AC — 50A 3P, AC Type | LS ELECTRIC | Frame: 50AF | Type: N-type (Normal/Standard) | Rated current (In): 50A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN60-A family. Frame: 60AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 60A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 1 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN60-A family. Frame: 60AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 60A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 1 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN63c/60A-A-TYPE | Metasol ELCB EBN60-A — 60A 3P, A Type | LS ELECTRIC | Frame: 60AF | Type: N-type (Normal/Standard) | Rated current (In): 60A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBN60-AC family. Frame: 60AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 60A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 1 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN60-AC family. Frame: 60AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 14kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 60A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 1 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN63c/60A | Metasol ELCB EBN60-AC — 60A 3P, AC Type | LS ELECTRIC | Frame: 60AF | Type: N-type (Normal/Standard) | Rated current (In): 60A | Breaking capacity Icu: 14kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBN630-AC family. Frame: 630AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 37kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBN630-AC family. Frame: 630AF | Type: N-type (Normal/Standard) | Breaking capacity Icu: 37kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBN603c/500A | Metasol ELCB EBN630-AC — 500A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: N-type (Normal/Standard) | Rated current (In): 500A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBN603c/630A | Metasol ELCB EBN630-AC — 630A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: N-type (Normal/Standard) | Rated current (In): 630A | Breaking capacity Icu: 37kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |