[LS ELECTRIC] — Metasol MT-225 Thermal Overload Relay (Class 10A/20)
Overload Relays LS ELECTRIC

[LS ELECTRIC] — Metasol MT-225 Thermal Overload Relay (Class 10A/20)

Family ID: LSE-MT-225

LS ELECTRIC Metasol MT-225 Thermal Overload Relay family. | Application: Motor overload protection (combined with MC contactor). | Frame: 225AF | Current setting range: 65~240A | Trip class: 10A (standard) and 20 (delayed) | Variants: 2H (3-pole 2-element), 3H (3-pole 3-element standard), 3K (phase-loss protection), 3D (Class 20 delayed) | Terminal: Screw(S), Lug(L) | Rated insulation Ui: 690V | Uimp: 6kV | Combined contactor: MC-185a, MC-225a | Standard: IEC60947-4-1 | Approval: IEC, UL — see RFQ table for specific MPN.

40 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MT-225/2H80S Metasol MT-225 2H 80A (65~100A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H80L Metasol MT-225 2H 80A (65~100A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H80S Metasol MT-225 3H 80A (65~100A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H80L Metasol MT-225 3H 80A (65~100A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K80S Metasol MT-225 3K 80A (65~100A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K80L Metasol MT-225 3K 80A (65~100A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H107S Metasol MT-225 2H 107A (85~125A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H107L Metasol MT-225 2H 107A (85~125A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H107S Metasol MT-225 3H 107A (85~125A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H107L Metasol MT-225 3H 107A (85~125A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K107S Metasol MT-225 3K 107A (85~125A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K107L Metasol MT-225 3K 107A (85~125A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H130S Metasol MT-225 2H 130A (100~160A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H130L Metasol MT-225 2H 130A (100~160A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H130S Metasol MT-225 3H 130A (100~160A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H130L Metasol MT-225 3H 130A (100~160A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K130S Metasol MT-225 3K 130A (100~160A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K130L Metasol MT-225 3K 130A (100~160A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H153S Metasol MT-225 2H 153A (120~185A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H153L Metasol MT-225 2H 153A (120~185A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H153S Metasol MT-225 3H 153A (120~185A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H153L Metasol MT-225 3H 153A (120~185A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K153S Metasol MT-225 3K 153A (120~185A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K153L Metasol MT-225 3K 153A (120~185A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H200S Metasol MT-225 2H 200A (160~240A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/2H200L Metasol MT-225 2H 200A (160~240A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Standard (3-pole 2-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H200S Metasol MT-225 3H 200A (160~240A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3H200L Metasol MT-225 3H 200A (160~240A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Standard (3-pole 3-element) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K200S Metasol MT-225 3K 200A (160~240A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3K200L Metasol MT-225 3K 200A (160~240A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 10A | Variant: Phase-loss protection | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D80S Metasol MT-225 3D (Class 20) 80A (65~100A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D80L Metasol MT-225 3D (Class 20) 80A (65~100A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 65~100A | Setting value: 80A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D107S Metasol MT-225 3D (Class 20) 107A (85~125A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D107L Metasol MT-225 3D (Class 20) 107A (85~125A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 85~125A | Setting value: 107A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D130S Metasol MT-225 3D (Class 20) 130A (100~160A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D130L Metasol MT-225 3D (Class 20) 130A (100~160A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 100~160A | Setting value: 130A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D153S Metasol MT-225 3D (Class 20) 153A (120~185A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D153L Metasol MT-225 3D (Class 20) 153A (120~185A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 120~185A | Setting value: 153A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D200S Metasol MT-225 3D (Class 20) 200A (160~240A range, Screw) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Screw | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL
MT-225/3D200L Metasol MT-225 3D (Class 20) 200A (160~240A range, Lug) LS ELECTRIC Frame: 225AF | Current range: 160~240A | Setting value: 200A | Trip class: 20 (delayed) | Variant: Phase-loss protection (delayed) | Terminal: Lug | Combined contactor: MC-185a, MC-225a | Rated insulation: 690V | Uimp: 6kV | Standard: IEC60947-4-1 | Approval: IEC, UL