[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T80 Magnetic Starter (80A AC-3, T80 Frame, TH-T100 Thermal)
Magnetic Starters MITSUBISHI ELECTRIC

[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T80 Magnetic Starter (80A AC-3, T80 Frame, TH-T100 Thermal)

Family ID: MEL-MSTR-T80

Mitsubishi Electric MS-T/N series T80-frame non-reversing open-type magnetic starter MSO-T80: AC-operated contactor combined with TH-T100 2-element thermal overload relay (manual reset standard). Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.

7 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSO-T80 67A AC24V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC24V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC48V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC48V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC100V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC100V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC200V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC200V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC300V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC300V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC400V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC400V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-T80 67A AC500V MSO-T80 non-reversing starter, T80 frame, 67A heater, AC500V coil Mitsubishi Electric Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4