[MITSUBISHI ELECTRIC] — MS-T/N Series MSOD-N150 Magnetic Starter (150A AC-3, N150 Frame, TH-N120(TA) Thermal)
Magnetic Starters MITSUBISHI ELECTRIC

[MITSUBISHI ELECTRIC] — MS-T/N Series MSOD-N150 Magnetic Starter (150A AC-3, N150 Frame, TH-N120(TA) Thermal)

Family ID: MEL-MSTR-D-N150

Mitsubishi Electric MS-T/N series N150-frame non-reversing open-type magnetic starter MSOD-N150: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.

48 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSOD-N150 42A DC12V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC24V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC48V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC100V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC110V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC125V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC200V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 42A DC220V MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC12V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC24V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC48V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC100V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC110V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC125V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC200V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 54A DC220V MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC12V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC24V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC48V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC100V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC110V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC125V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC200V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 67A DC220V MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC12V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC24V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC48V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC100V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC110V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC125V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC200V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 82A DC220V MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC12V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC24V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC48V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC100V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC110V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC125V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC200V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 105A DC220V MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC12V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC12V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC24V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC48V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC100V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC110V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC110V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC125V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC125V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC200V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSOD-N150 125A DC220V MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC220V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4