Mitsubishi Electric TH-T65 / TH-T65KP thermal overload relay for MS-T/N series magnetic contactors and starters, t65 frame, heater designations 15-54A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
12 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| TH-T65 15A | TH-T65 thermal relay, 15A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 15A (adjustable 12-18A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65 22A | TH-T65 thermal relay, 22A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 22A (adjustable 18-26A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65 29A | TH-T65 thermal relay, 29A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 29A (adjustable 24-34A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65 35A | TH-T65 thermal relay, 35A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 35A (adjustable 30-40A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65 42A | TH-T65 thermal relay, 42A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 42A (adjustable 34-50A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65 54A | TH-T65 thermal relay, 54A heater, 2-element | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 2-element · Protection: Overload · Heater: 54A (adjustable 43-65A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 15A | TH-T65KP thermal relay, 15A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 22A | TH-T65KP thermal relay, 22A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 29A | TH-T65KP thermal relay, 29A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 35A | TH-T65KP thermal relay, 35A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 42A | TH-T65KP thermal relay, 42A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T65KP 54A | TH-T65KP thermal relay, 54A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 · Type: Thermal Overload Relay · Elements: 3-element (2E) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · Mounting: For magnetic starter combination · Reset: Manual (standard) · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |