[Yuken] — Pilot Operated Flow Control and Check Valve (FHCG)
Family ID: YUK-FC-FHCG
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
16 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| FHCG-02-30-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | ||
| FHCG-02-30-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | ||
| FHCG-02-30-N-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | ||
| FHCG-02-30-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | ||
| FHCG-03-125-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | ||
| FHCG-03-125-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | ||
| FHCG-03-125-N-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | ||
| FHCG-03-125-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | ||
| FHCG-06-250-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | ||
| FHCG-06-250-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | ||
| FHCG-06-250-N-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | ||
| FHCG-06-250-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | ||
| FHCG-10-500-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | ||
| FHCG-10-500-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | ||
| FHCG-10-500-N-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | ||
| FHCG-10-500-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |