LS Electric EBE50Fb-50mA Beyond X Industrial Distribution Panel MCB/RCBO (E-type RCBO (Economy, Hydraulic-Magnetic), 50AF RCBO, 2.5kA @ 220V AC / 1.5kA @ 380V AC, 50mA, 15~50A)

LS Electric EBE50Fb-50mA Beyond X Industrial Distribution Panel MCB/RCBO (E-type RCBO (Economy, Hydraulic-Magnetic), 50AF RCBO, 2.5kA @ 220V AC / 1.5kA @ 380V AC, 50mA, 15~50A)

LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE50Fb-50mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Rated current (In): 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 50mA: 15A and above only | 10 variants — see RFQ table for specific MPN.

Specifications

Frame 50AF
Type E-type RCBO (Economy, Hydraulic-Magnetic)
Breaking capacity Icn 2.5kA @ 220V AC / 1.5kA @ 380V AC
Ics 100% Icn
Trip method Hydraulic-Magnetic + RCD
Trip curve (7~15)×In
Sensitivity (I△n) 50mA
Operating time ≤0.03s
Uimp 4kV
Mounting Screw or DIN rail
Voltage AC 110/220V (2P) / 220/380V (3P)
Standard KSC 8321 / KSC 4613 / IEC 60947-2
EBE52Fb/15/50 EBE Fb EBE50Fb-50mA — EBE52Fb 15A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/20/50 EBE Fb EBE50Fb-50mA — EBE52Fb 20A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/30/50 EBE Fb EBE50Fb-50mA — EBE52Fb 30A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/40/50 EBE Fb EBE50Fb-50mA — EBE52Fb 40A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/50/50 EBE Fb EBE50Fb-50mA — EBE52Fb 50A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/15/50 EBE Fb EBE50Fb-50mA — EBE53Fb 15A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/20/50 EBE Fb EBE50Fb-50mA — EBE53Fb 20A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/30/50 EBE Fb EBE50Fb-50mA — EBE53Fb 30A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/40/50 EBE Fb EBE50Fb-50mA — EBE53Fb 40A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/50/50 EBE Fb EBE50Fb-50mA — EBE53Fb 50A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
Miniature Circuit BreakersLS Electric
10 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric EBE50Fb-50mA Beyond X Industrial Distribution Panel MCB/RCBO (E-type RCBO (Economy, Hydraulic-Magnetic), 50AF RCBO, 2.5kA @ 220V AC / 1.5kA @ 380V AC, 50mA, 15~50A)

Brand LS Electric·Miniature Circuit Breakers

Available part numbers (10)

EBE52Fb/15/50, EBE52Fb/20/50, EBE52Fb/30/50, EBE52Fb/40/50, EBE52Fb/50/50, EBE53Fb/15/50, EBE53Fb/20/50, EBE53Fb/30/50, EBE53Fb/40/50, EBE53Fb/50/50

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
EBE52Fb/15/50EBE Fb EBE50Fb-50mA — EBE52Fb 15A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/20/50EBE Fb EBE50Fb-50mA — EBE52Fb 20A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/30/50EBE Fb EBE50Fb-50mA — EBE52Fb 30A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/40/50EBE Fb EBE50Fb-50mA — EBE52Fb 40A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE52Fb/50/50EBE Fb EBE50Fb-50mA — EBE52Fb 50A 2P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/15/50EBE Fb EBE50Fb-50mA — EBE53Fb 15A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/20/50EBE Fb EBE50Fb-50mA — EBE53Fb 20A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/30/50EBE Fb EBE50Fb-50mA — EBE53Fb 30A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/40/50EBE Fb EBE50Fb-50mA — EBE53Fb 40A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only
EBE53Fb/50/50EBE Fb EBE50Fb-50mA — EBE53Fb 50A 3P (RCBO) | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only

Need a different model, or a part not listed here? Send us your parts list →