Skip to product information
1 of 1

LS Electric EBH50-A Metasol ELCB (H-type (High breaking capacity), 50kA @ 415V, A Type, 15~50A)

LS Electric EBH50-A Metasol ELCB (H-type (High breaking capacity), 50kA @ 415V, A Type, 15~50A)

LS ELECTRIC Metasol ELCB EBH50-A family.

Specifications

Frame 50AF
Type H-type (High breaking capacity)
Breaking capacity Icu 50kA @ 415V AC AC
Leakage type A Type
Detection AC + Pulsating DC leakage current detection
Sensitivity (rated I△n) 30mA / 100mA / 100·200·500mA (selectable)
Operating time ≤0.1s (high-speed type)
Standard KS C 4613 / IEC 60947-2
Application EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/15A-A-TYPE Metasol ELCB EBH50-A — 15A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/15A-A-TYPE Metasol ELCB EBH50-A — 15A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/16A-A-TYPE Metasol ELCB EBH50-A — 16A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/16A-A-TYPE Metasol ELCB EBH50-A — 16A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/20A-A-TYPE Metasol ELCB EBH50-A — 20A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/20A-A-TYPE Metasol ELCB EBH50-A — 20A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/25A-A-TYPE Metasol ELCB EBH50-A — 25A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/25A-A-TYPE Metasol ELCB EBH50-A — 25A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/30A-A-TYPE Metasol ELCB EBH50-A — 30A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/30A-A-TYPE Metasol ELCB EBH50-A — 30A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/32A-A-TYPE Metasol ELCB EBH50-A — 32A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/32A-A-TYPE Metasol ELCB EBH50-A — 32A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/40A-A-TYPE Metasol ELCB EBH50-A — 40A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/40A-A-TYPE Metasol ELCB EBH50-A — 40A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/50A-A-TYPE Metasol ELCB EBH50-A — 50A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/50A-A-TYPE Metasol ELCB EBH50-A — 50A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
Earth Leakage Circuit BreakersLS Electric
16 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric EBH50-A Metasol ELCB (H-type (High breaking capacity), 50kA @ 415V, A Type, 15~50A)

Brand LS Electric·Earth Leakage Circuit Breakers

Available part numbers (16)

EBH53c/15A-A-TYPE, EBH54c/15A-A-TYPE, EBH53c/16A-A-TYPE, EBH54c/16A-A-TYPE, EBH53c/20A-A-TYPE, EBH54c/20A-A-TYPE, EBH53c/25A-A-TYPE, EBH54c/25A-A-TYPE, EBH53c/30A-A-TYPE, EBH54c/30A-A-TYPE + 6 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
EBH53c/15A-A-TYPEMetasol ELCB EBH50-A — 15A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/15A-A-TYPEMetasol ELCB EBH50-A — 15A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/16A-A-TYPEMetasol ELCB EBH50-A — 16A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/16A-A-TYPEMetasol ELCB EBH50-A — 16A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/20A-A-TYPEMetasol ELCB EBH50-A — 20A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/20A-A-TYPEMetasol ELCB EBH50-A — 20A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/25A-A-TYPEMetasol ELCB EBH50-A — 25A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/25A-A-TYPEMetasol ELCB EBH50-A — 25A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/30A-A-TYPEMetasol ELCB EBH50-A — 30A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/30A-A-TYPEMetasol ELCB EBH50-A — 30A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/32A-A-TYPEMetasol ELCB EBH50-A — 32A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/32A-A-TYPEMetasol ELCB EBH50-A — 32A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/40A-A-TYPEMetasol ELCB EBH50-A — 40A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/40A-A-TYPEMetasol ELCB EBH50-A — 40A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH53c/50A-A-TYPEMetasol ELCB EBH50-A — 50A 3P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers
EBH54c/50A-A-TYPEMetasol ELCB EBH50-A — 50A 4P, A Type | Frame: 50AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers

Need a different model, or a part not listed here? Send us your parts list →