Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| MMS-32S/1.6A | Metasol MMS-32S 1.6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/1.6A O-RING TERMINAL | Metasol MMS-32S 1.6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/2.5A | Metasol MMS-32S 2.5A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/2.5A O-RING TERMINAL | Metasol MMS-32S 2.5A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/4A | Metasol MMS-32S 4A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/4A O-RING TERMINAL | Metasol MMS-32S 4A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/6A | Metasol MMS-32S 6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/6A O-RING TERMINAL | Metasol MMS-32S 6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/8A | Metasol MMS-32S 8A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/8A O-RING TERMINAL | Metasol MMS-32S 8A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/10A | Metasol MMS-32S 10A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | ||
| MMS-32S/10A O-RING TERMINAL | Metasol MMS-32S 10A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Need a different model, or a part not listed here? Send us your parts list →