Skip to product information
1 of 1

LS Electric Metasol MMS-32S Standard Manual Motor Starter (32AF, Low Range 1.6~10A, 3-Pole, Toggle Handle)

LS Electric Metasol MMS-32S Standard Manual Motor Starter (32AF, Low Range 1.6~10A, 3-Pole, Toggle Handle)

Metasol MMS-32S Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device.

Key features

  • Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection
  • Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V)
  • Frame: 32AF, width 45mm
  • Rated insulation voltage Ui = 690V, impulse Uimp = 6kV
  • Up to 690V Ue, 50/60Hz
  • Mechanical life 100,000 ops, electrical life 100,000 ops

Specifications

Frame 32AF
Capacity Band Low Range (1.6~10A)
Type Standard (S)
Pole 3-Pole
Rated Voltage Ue Up to 690V AC, 50/60Hz
Rated Insulation Ui 690V
Impulse Uimp 6kV
Overload Protection Class 10 (thermal, adjustable)
Phase-Loss Protection Yes
Handle Toggle
Trip Test Button Yes
Trip Cause Indicator No
MMS-32S/1.6A Metasol MMS-32S 1.6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/1.6A O-RING TERMINAL Metasol MMS-32S 1.6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/2.5A Metasol MMS-32S 2.5A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/2.5A O-RING TERMINAL Metasol MMS-32S 2.5A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/4A Metasol MMS-32S 4A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/4A O-RING TERMINAL Metasol MMS-32S 4A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/6A Metasol MMS-32S 6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/6A O-RING TERMINAL Metasol MMS-32S 6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/8A Metasol MMS-32S 8A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/8A O-RING TERMINAL Metasol MMS-32S 8A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/10A Metasol MMS-32S 10A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/10A O-RING TERMINAL Metasol MMS-32S 10A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
Manual Motor StartersLS Electric
12 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric Metasol MMS-32S Standard Manual Motor Starter (32AF, Low Range 1.6~10A, 3-Pole, Toggle Handle)

Brand LS Electric·Manual Motor Starters

Available part numbers (12)

MMS-32S/1.6A, MMS-32S/1.6A O-RING TERMINAL, MMS-32S/2.5A, MMS-32S/2.5A O-RING TERMINAL, MMS-32S/4A, MMS-32S/4A O-RING TERMINAL, MMS-32S/6A, MMS-32S/6A O-RING TERMINAL, MMS-32S/8A, MMS-32S/8A O-RING TERMINAL + 2 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
MMS-32S/1.6AMetasol MMS-32S 1.6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/1.6A O-RING TERMINALMetasol MMS-32S 1.6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW | 400V/0.55kW | 690V/1.1kW | 230V/1/3HP | 460V/3/4HP | 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/2.5AMetasol MMS-32S 2.5A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/2.5A O-RING TERMINALMetasol MMS-32S 2.5A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW | 400V/0.75kW | 690V/1.5kW | 230V/1/2HP | 460V/1-1/2HP | 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/4AMetasol MMS-32S 4A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/4A O-RING TERMINALMetasol MMS-32S 4A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW | 400V/1.5kW | 690V/3kW | 230V/1HP | 460V/2HP | 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/6AMetasol MMS-32S 6A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/6A O-RING TERMINALMetasol MMS-32S 6A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/2.2kW | 690V/4kW | 230V/1-1/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/8AMetasol MMS-32S 8A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/8A O-RING TERMINALMetasol MMS-32S 8A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW | 400V/3kW | 690V/5.5kW | 230V/2HP | 460V/5HP | 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/10AMetasol MMS-32S 10A, Standard terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-32S/10A O-RING TERMINALMetasol MMS-32S 10A, O-Ring Terminal terminal, Standard (Low Range) | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW | 400V/4kW | 690V/7.5kW | 230V/3HP | 460V/7-1/2HP | 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC