LS ELECTRIC Susol MCCB TD100N-FTU family.

Specifications

Frame 100AF
Breaking capacity Icu 50kA @ 415V AC
Trip unit FTU100 (Thermal-Magnetic)
Trip features Fixed rated current and instantaneous trip (10×In)
Standard IEC 60947-2
TD100N-FTU100-16A-2P Susol MCCB TD100N-FTU — 16A FTU100, 2-pole | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-16A-3P Susol MCCB TD100N-FTU — 16A FTU100, 3-pole | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-16A-4PL Susol MCCB TD100N-FTU — 16A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-2P Susol MCCB TD100N-FTU — 20A FTU100, 2-pole | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-3P Susol MCCB TD100N-FTU — 20A FTU100, 3-pole | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-4PL Susol MCCB TD100N-FTU — 20A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-2P Susol MCCB TD100N-FTU — 25A FTU100, 2-pole | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-3P Susol MCCB TD100N-FTU — 25A FTU100, 3-pole | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-4PL Susol MCCB TD100N-FTU — 25A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-2P Susol MCCB TD100N-FTU — 32A FTU100, 2-pole | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-3P Susol MCCB TD100N-FTU — 32A FTU100, 3-pole | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-4PL Susol MCCB TD100N-FTU — 32A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-2P Susol MCCB TD100N-FTU — 40A FTU100, 2-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-3P Susol MCCB TD100N-FTU — 40A FTU100, 3-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-4PL Susol MCCB TD100N-FTU — 40A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-2P Susol MCCB TD100N-FTU — 50A FTU100, 2-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-3P Susol MCCB TD100N-FTU — 50A FTU100, 3-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-4PL Susol MCCB TD100N-FTU — 50A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-2P Susol MCCB TD100N-FTU — 63A FTU100, 2-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-3P Susol MCCB TD100N-FTU — 63A FTU100, 3-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-4PL Susol MCCB TD100N-FTU — 63A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-2P Susol MCCB TD100N-FTU — 80A FTU100, 2-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-3P Susol MCCB TD100N-FTU — 80A FTU100, 3-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-4PL Susol MCCB TD100N-FTU — 80A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-2P Susol MCCB TD100N-FTU — 100A FTU100, 2-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-3P Susol MCCB TD100N-FTU — 100A FTU100, 3-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-4PL Susol MCCB TD100N-FTU — 100A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
Molded Case Circuit BreakersLS Electric
27 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric TD100N-FTU Susol MCCB (Normal (Standard), 50kA @ 415V, FTU 16~100A)

Brand LS Electric·Molded Case Circuit Breakers

Available part numbers (27)

TD100N-FTU100-16A-2P, TD100N-FTU100-16A-3P, TD100N-FTU100-16A-4PL, TD100N-FTU100-20A-2P, TD100N-FTU100-20A-3P, TD100N-FTU100-20A-4PL, TD100N-FTU100-25A-2P, TD100N-FTU100-25A-3P, TD100N-FTU100-25A-4PL, TD100N-FTU100-32A-2P + 17 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
TD100N-FTU100-16A-2PSusol MCCB TD100N-FTU — 16A FTU100, 2-pole | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-16A-3PSusol MCCB TD100N-FTU — 16A FTU100, 3-pole | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-16A-4PLSusol MCCB TD100N-FTU — 16A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-2PSusol MCCB TD100N-FTU — 20A FTU100, 2-pole | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-3PSusol MCCB TD100N-FTU — 20A FTU100, 3-pole | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-20A-4PLSusol MCCB TD100N-FTU — 20A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-2PSusol MCCB TD100N-FTU — 25A FTU100, 2-pole | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-3PSusol MCCB TD100N-FTU — 25A FTU100, 3-pole | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-25A-4PLSusol MCCB TD100N-FTU — 25A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-2PSusol MCCB TD100N-FTU — 32A FTU100, 2-pole | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-3PSusol MCCB TD100N-FTU — 32A FTU100, 3-pole | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-32A-4PLSusol MCCB TD100N-FTU — 32A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-2PSusol MCCB TD100N-FTU — 40A FTU100, 2-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-3PSusol MCCB TD100N-FTU — 40A FTU100, 3-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-40A-4PLSusol MCCB TD100N-FTU — 40A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-2PSusol MCCB TD100N-FTU — 50A FTU100, 2-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-3PSusol MCCB TD100N-FTU — 50A FTU100, 3-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-50A-4PLSusol MCCB TD100N-FTU — 50A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-2PSusol MCCB TD100N-FTU — 63A FTU100, 2-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-3PSusol MCCB TD100N-FTU — 63A FTU100, 3-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-63A-4PLSusol MCCB TD100N-FTU — 63A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-2PSusol MCCB TD100N-FTU — 80A FTU100, 2-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-3PSusol MCCB TD100N-FTU — 80A FTU100, 3-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-80A-4PLSusol MCCB TD100N-FTU — 80A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-2PSusol MCCB TD100N-FTU — 100A FTU100, 2-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-3PSusol MCCB TD100N-FTU — 100A FTU100, 3-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TD100N-FTU100-100A-4PLSusol MCCB TD100N-FTU — 100A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV

Need a different model, or a part not listed here? Send us your parts list →