Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| TS100H-FTU100-40A-2P | Susol MCCB TS100H-FTU — 40A FTU100, 2-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-40A-3P | Susol MCCB TS100H-FTU — 40A FTU100, 3-pole | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-40A-4PL | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-40A-4PR | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (R) | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-50A-2P | Susol MCCB TS100H-FTU — 50A FTU100, 2-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-50A-3P | Susol MCCB TS100H-FTU — 50A FTU100, 3-pole | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-50A-4PL | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-50A-4PR | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (R) | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-63A-2P | Susol MCCB TS100H-FTU — 63A FTU100, 2-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-63A-3P | Susol MCCB TS100H-FTU — 63A FTU100, 3-pole | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-63A-4PL | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-63A-4PR | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (R) | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-80A-2P | Susol MCCB TS100H-FTU — 80A FTU100, 2-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-80A-3P | Susol MCCB TS100H-FTU — 80A FTU100, 3-pole | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-80A-4PL | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-80A-4PR | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (R) | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-100A-2P | Susol MCCB TS100H-FTU — 100A FTU100, 2-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-100A-3P | Susol MCCB TS100H-FTU — 100A FTU100, 3-pole | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-100A-4PL | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (L) | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole left (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100H-FTU100-100A-4PR | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (R) | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N-pole right (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
Need a different model, or a part not listed here? Send us your parts list →