Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| TS100Ni-ETSi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETSi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETSi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETSi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETSi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETSi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETMi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETMi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETMi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETHi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETHi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETHi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETLi, 3-pole | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETLi, 4-pole (L) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETLi, 4-pole (R) | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETSi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETSi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETSi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETSi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETSi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETSi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETMi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETMi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETMi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETMi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETHi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETHi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETHi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETHi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETLi, 3-pole | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETLi, 4-pole (L) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | ||
| TS100Ni-ETLi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETLi, 4-pole (R) | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
Need a different model, or a part not listed here? Send us your parts list →