Skip to product information
1 of 1

LS Electric TS400Hi Susol Smart MCCB (High, 85kA @ 415V)

LS Electric TS400Hi Susol Smart MCCB (High, 85kA @ 415V)

LS ELECTRIC Susol Smart MCCB TS400Hi family.

Specifications

Frame 400AF
Breaking capacity Icu 85kA @ 415V AC
Standard IEC 60947-2
TS400Hi-ETSi-250A-3P Susol Smart MCCB TS400Hi — 250A ETSi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-250A-4PL Susol Smart MCCB TS400Hi — 250A ETSi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-250A-4PR Susol Smart MCCB TS400Hi — 250A ETSi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-3P Susol Smart MCCB TS400Hi — 250A ETMi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-4PL Susol Smart MCCB TS400Hi — 250A ETMi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-4PR Susol Smart MCCB TS400Hi — 250A ETMi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-3P Susol Smart MCCB TS400Hi — 250A ETHi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-4PL Susol Smart MCCB TS400Hi — 250A ETHi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-4PR Susol Smart MCCB TS400Hi — 250A ETHi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-3P Susol Smart MCCB TS400Hi — 250A ETLi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-4PL Susol Smart MCCB TS400Hi — 250A ETLi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-4PR Susol Smart MCCB TS400Hi — 250A ETLi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-3P Susol Smart MCCB TS400Hi — 400A ETSi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-4PL Susol Smart MCCB TS400Hi — 400A ETSi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-4PR Susol Smart MCCB TS400Hi — 400A ETSi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-3P Susol Smart MCCB TS400Hi — 400A ETMi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-4PL Susol Smart MCCB TS400Hi — 400A ETMi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-4PR Susol Smart MCCB TS400Hi — 400A ETMi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-3P Susol Smart MCCB TS400Hi — 400A ETHi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-4PL Susol Smart MCCB TS400Hi — 400A ETHi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-4PR Susol Smart MCCB TS400Hi — 400A ETHi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-3P Susol Smart MCCB TS400Hi — 400A ETLi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-4PL Susol Smart MCCB TS400Hi — 400A ETLi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-4PR Susol Smart MCCB TS400Hi — 400A ETLi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
Molded Case Circuit BreakersLS Electric
24 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

LS Electric TS400Hi Susol Smart MCCB (High, 85kA @ 415V)

Brand LS Electric·Molded Case Circuit Breakers

Available part numbers (24)

TS400Hi-ETSi-250A-3P, TS400Hi-ETSi-250A-4PL, TS400Hi-ETSi-250A-4PR, TS400Hi-ETMi-250A-3P, TS400Hi-ETMi-250A-4PL, TS400Hi-ETMi-250A-4PR, TS400Hi-ETHi-250A-3P, TS400Hi-ETHi-250A-4PL, TS400Hi-ETHi-250A-4PR, TS400Hi-ETLi-250A-3P + 14 more — see full table ↓

How to order

Send the LS Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
TS400Hi-ETSi-250A-3PSusol Smart MCCB TS400Hi — 250A ETSi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-250A-4PLSusol Smart MCCB TS400Hi — 250A ETSi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-250A-4PRSusol Smart MCCB TS400Hi — 250A ETSi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-3PSusol Smart MCCB TS400Hi — 250A ETMi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-4PLSusol Smart MCCB TS400Hi — 250A ETMi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-250A-4PRSusol Smart MCCB TS400Hi — 250A ETMi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-3PSusol Smart MCCB TS400Hi — 250A ETHi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-4PLSusol Smart MCCB TS400Hi — 250A ETHi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-250A-4PRSusol Smart MCCB TS400Hi — 250A ETHi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-3PSusol Smart MCCB TS400Hi — 250A ETLi, 3-pole | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-4PLSusol Smart MCCB TS400Hi — 250A ETLi, 4-pole (L) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-250A-4PRSusol Smart MCCB TS400Hi — 250A ETLi, 4-pole (R) | Frame: 400AF | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-3PSusol Smart MCCB TS400Hi — 400A ETSi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-4PLSusol Smart MCCB TS400Hi — 400A ETSi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETSi-400A-4PRSusol Smart MCCB TS400Hi — 400A ETSi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-3PSusol Smart MCCB TS400Hi — 400A ETMi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-4PLSusol Smart MCCB TS400Hi — 400A ETMi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETMi-400A-4PRSusol Smart MCCB TS400Hi — 400A ETMi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-3PSusol Smart MCCB TS400Hi — 400A ETHi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-4PLSusol Smart MCCB TS400Hi — 400A ETHi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETHi-400A-4PRSusol Smart MCCB TS400Hi — 400A ETHi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-3PSusol Smart MCCB TS400Hi — 400A ETLi, 3-pole | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 140×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-4PLSusol Smart MCCB TS400Hi — 400A ETLi, 4-pole (L) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole left (N-A-B-C) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS400Hi-ETLi-400A-4PRSusol Smart MCCB TS400Hi — 400A ETLi, 4-pole (R) | Frame: 400AF | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N-pole right (A-B-C-N) | Dimensions (W×H×D): 186.5×260×110 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV

Need a different model, or a part not listed here? Send us your parts list →