Mitsubishi Electric MS-T/N series DU-N180 DC magnetic contactor for DC motor control and general DC circuit switching at DC440V and below, including variable speed drive applications and dynamic braking.

Key features

  • AC operated coil with 2a1b main contacts and 2a2b twin auxiliary contacts applicable down to DC20V 5mA
  • Rated capacity 22kW at DC110V, 35kW at DC220V, 45kW at DC440V in two-pole series connection, open thermal current 270A, rated insulation voltage 660V, coil power consumption 4.2W
  • Reversing type DU-2XN180 is available on the same frame
  • Auxiliary contact units UN-AX and charged-part protection cover units UN-CZ from the MS-N series are applicable
  • Mechanical durability 2,500,000 operations, electrical durability 500,000 operations at 1200 operations per hour
  • Compliant with JEM1038 DC2 and DC4 class and JIS C8201-5-1

Specifications

Type DC magnetic contactor for DC440V or less
Frame DU-N180
Operation AC operated
Main Contact 2a1b
Aux Contact 2a2b
Breaking Capacity 2-Pole Series 960A at DC110V, 720A at DC220V, 480A at DC440V
Closing Current Capacity 960A
Open Thermal Current Ith 270A on a contact, 260A on b contact
Rated Insulation Voltage 660V
Coil Power Consumption 4.2W
Switching Frequency 1200 operations/h
Durability Mechanical 2,500,000 operations, Electrical 500,000 operations
DU-N180 AC48V DU-N180 DC contactor, AC48V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC48V DU-2XN180 DC contactor, AC48V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC100V DU-N180 DC contactor, AC100V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC100V DU-2XN180 DC contactor, AC100V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC200V DU-N180 DC contactor, AC200V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC200V DU-2XN180 DC contactor, AC200V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC300V DU-N180 DC contactor, AC300V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC300V DU-2XN180 DC contactor, AC300V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC400V DU-N180 DC contactor, AC400V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC400V DU-2XN180 DC contactor, AC400V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC500V DU-N180 DC contactor, AC500V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC500V DU-2XN180 DC contactor, AC500V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
Magnetic ContactorsMitsubishi Electric
12 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric - DU-N180 DC Magnetic Contactor (AC Operated, 2a1b Main, 35kW at DC220V)

Brand Mitsubishi Electric·Magnetic Contactors

Available part numbers (12)

DU-N180 AC48V, DU-2XN180 AC48V, DU-N180 AC100V, DU-2XN180 AC100V, DU-N180 AC200V, DU-2XN180 AC200V, DU-N180 AC300V, DU-2XN180 AC300V, DU-N180 AC400V, DU-2XN180 AC400V + 2 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
DU-N180 AC48VDU-N180 DC contactor, AC48V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC48VDU-2XN180 DC contactor, AC48V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC100VDU-N180 DC contactor, AC100V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC100VDU-2XN180 DC contactor, AC100V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC200VDU-N180 DC contactor, AC200V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC200VDU-2XN180 DC contactor, AC200V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC300VDU-N180 DC contactor, AC300V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC300VDU-2XN180 DC contactor, AC300V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC400VDU-N180 DC contactor, AC400V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC400VDU-2XN180 DC contactor, AC400V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-N180 AC500VDU-N180 DC contactor, AC500V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1
DU-2XN180 AC500VDU-2XN180 DC contactor, AC500V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N180 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 22kW at DC110V, 35kW at DC220V, 45kW at DC440V | Rated Current General DC Motor 2-Pole Series: 240A at DC110V, 180A at DC220V, 120A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 260A at DC110V, 260A at DC220V, 260A at DC440V | Breaking Capacity 2-Pole Series: 960A at DC110V, 720A at DC220V, 480A at DC440V | Closing Current Capacity: 960A | Open Thermal Current Ith: 270A on a contact, 260A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 4.2W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1

Need a different model, or a part not listed here? Send us your parts list →