Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| DU-N60 AC24V | DU-N60 DC contactor, AC24V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC24V | Coil Rating: 24V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC24V | DU-2XN60 DC contactor, AC24V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC24V | Coil Rating: 24V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC48V | DU-N60 DC contactor, AC48V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC48V | DU-2XN60 DC contactor, AC48V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC48V | Coil Rating: 48-50V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC100V | DU-N60 DC contactor, AC100V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC100V | DU-2XN60 DC contactor, AC100V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC100V | Coil Rating: 100-127V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC200V | DU-N60 DC contactor, AC200V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC200V | DU-2XN60 DC contactor, AC200V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC200V | Coil Rating: 200-240V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC300V | DU-N60 DC contactor, AC300V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC300V | DU-2XN60 DC contactor, AC300V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC300V | Coil Rating: 260-350V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC400V | DU-N60 DC contactor, AC400V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC400V | DU-2XN60 DC contactor, AC400V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC400V | Coil Rating: 380-440V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-N60 AC500V | DU-N60 DC contactor, AC500V coil, 2a1b main contacts, non-reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Non-reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 | ||
| DU-2XN60 AC500V | DU-2XN60 DC contactor, AC500V coil, 2a1b main contacts, reversing | Type: DC magnetic contactor for DC440V or less | Frame: DU-N60 | Configuration: Reversing | Operation: AC operated | Main Contact: 2a1b | Coil Designation: AC500V | Coil Rating: 460-550V 50/60Hz | Aux Contact: 2a2b | Rated Capacity General DC Motor 2-Pole Series: 7.5kW at DC110V, 11kW at DC220V, 15kW at DC440V | Rated Current General DC Motor 2-Pole Series: 80A at DC110V, 60A at DC220V, 40A at DC440V | Rated Current Variable Speed Control 2-Pole Series: 90A at DC110V, 90A at DC220V, 80A at DC440V | Breaking Capacity 2-Pole Series: 320A at DC110V, 240A at DC220V, 160A at DC440V | Closing Current Capacity: 320A | Open Thermal Current Ith: 120A on a contact, 100A on b contact | Rated Insulation Voltage: 660V | Coil Power Consumption: 2.9W | Switching Frequency: 1200 operations/h | Durability: Mechanical 2,500,000 operations, Electrical 500,000 operations | Standards: JEM1038 DC2 and DC4 class, JIS C8201-5-1 |