Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| MSO-N400 105A AC48V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 105A AC100V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 105A AC200V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 105A AC300V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 105A AC400V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 105A AC500V | MSO-N400 non-reversing starter, N400 frame, 105A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 105A (adjustable 85-125A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC48V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC100V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC200V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC300V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC400V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 125A AC500V | MSO-N400 non-reversing starter, N400 frame, 125A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 125A (adjustable 100-150A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC48V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC100V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC200V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC300V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC400V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 150A AC500V | MSO-N400 non-reversing starter, N400 frame, 150A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 150A (adjustable 120-180A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC48V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC100V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC200V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC300V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC400V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 180A AC500V | MSO-N400 non-reversing starter, N400 frame, 180A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 180A (adjustable 140-220A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC48V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC100V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC200V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC300V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC400V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 250A AC500V | MSO-N400 non-reversing starter, N400 frame, 250A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 250A (adjustable 200-300A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC48V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC48V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC100V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC100V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC200V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC200V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC300V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC300V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC400V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC400V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-N400 330A AC500V | MSO-N400 non-reversing starter, N400 frame, 330A heater, AC500V coil | Frame: N400 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-N400RH (2-element, manual reset) | Heater: 330A (adjustable 260-400A) | AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V | AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V | AC-1 Current: 450A@200-220V / 450A@380-440V | Thermal Current Ith: 450A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Need a different model, or a part not listed here? Send us your parts list →