| Product code | Spec | ||
|---|---|---|---|
| MSO-T65KP 15A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 15A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 22A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 29A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 29A (adjustable 24-34A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 35A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 35A (adjustable 30-40A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 42A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 42A (adjustable 34-50A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC24V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC48V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC100V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC200V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC300V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC400V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T65KP 54A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC500V coil | Frame: T65 | Type: Non-Reversing Magnetic Starter (Open Type) | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | Thermal Relay: TH-T65KP (3-element 2E, manual reset) | Protection: Overload + Open-phase | Heater: 54A (adjustable 43-65A) | AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V | AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V | AC-1 Current: 100A@200-220V / 100A@380-440V | Thermal Current Ith: 100A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |