Mitsubishi Electric MS-T/N series T100-frame non-reversing magnetic contactor S-T100 / SD-T100, rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, conventional thermal current Ith 150A.

Key features

  • Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability
  • AC operating coils AC24V-AC500V (S type) and DC coils DC12V-DC220V (SD type)
  • Standard auxiliary contacts: 2a2b

Specifications

Frame T100
Type Non-Reversing Magnetic Contactor
Poles 3
AC-3 Capacity 22kW@200-220V / 45kW@380-440V / 45kW@500-550V
AC-3 Current 100A@200-220V / 93A@380-440V / 75A@500-550V
AC-1 Current 150A@200-220V / 150A@380-440V
Thermal Current Ith 150A
Aux Contact 2a2b
Standards JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC24V S-T100 non-reversing contactor, T100 frame, AC24V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC48V S-T100 non-reversing contactor, T100 frame, AC48V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC100V S-T100 non-reversing contactor, T100 frame, AC100V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC200V S-T100 non-reversing contactor, T100 frame, AC200V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC300V S-T100 non-reversing contactor, T100 frame, AC300V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC400V S-T100 non-reversing contactor, T100 frame, AC400V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC500V S-T100 non-reversing contactor, T100 frame, AC500V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC12V SD-T100 non-reversing contactor, T100 frame, DC12V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC24V SD-T100 non-reversing contactor, T100 frame, DC24V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC48V SD-T100 non-reversing contactor, T100 frame, DC48V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC100V SD-T100 non-reversing contactor, T100 frame, DC100V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC110V SD-T100 non-reversing contactor, T100 frame, DC110V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC125V SD-T100 non-reversing contactor, T100 frame, DC125V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC200V SD-T100 non-reversing contactor, T100 frame, DC200V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC220V SD-T100 non-reversing contactor, T100 frame, DC220V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
Magnetic ContactorsMitsubishi Electric
15 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric MS-T/N Series S-T100 / SD-T100 Magnetic Contactor (100A AC-3, T100 Frame)

Brand Mitsubishi Electric·Magnetic Contactors

Available part numbers (15)

S-T100 AC24V, S-T100 AC48V, S-T100 AC100V, S-T100 AC200V, S-T100 AC300V, S-T100 AC400V, S-T100 AC500V, SD-T100 DC12V, SD-T100 DC24V, SD-T100 DC48V + 5 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
S-T100 AC24VS-T100 non-reversing contactor, T100 frame, AC24V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC24V (24V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC48VS-T100 non-reversing contactor, T100 frame, AC48V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC48V (48-50V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC100VS-T100 non-reversing contactor, T100 frame, AC100V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC100V (100-127V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC200VS-T100 non-reversing contactor, T100 frame, AC200V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC200V (200-240V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC300VS-T100 non-reversing contactor, T100 frame, AC300V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC300V (260-350V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC400VS-T100 non-reversing contactor, T100 frame, AC400V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC400V (380-440V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
S-T100 AC500VS-T100 non-reversing contactor, T100 frame, AC500V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: AC operated | Coil: AC500V (460-550V 50/60Hz) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC12VSD-T100 non-reversing contactor, T100 frame, DC12V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC12V (DC12V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC24VSD-T100 non-reversing contactor, T100 frame, DC24V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC24V (DC24V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC48VSD-T100 non-reversing contactor, T100 frame, DC48V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC48V (DC48V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC100VSD-T100 non-reversing contactor, T100 frame, DC100V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC100V (DC100V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC110VSD-T100 non-reversing contactor, T100 frame, DC110V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC110V (DC110V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC125VSD-T100 non-reversing contactor, T100 frame, DC125V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC125V (DC120-125V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC200VSD-T100 non-reversing contactor, T100 frame, DC200V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC200V (DC200V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
SD-T100 DC220VSD-T100 non-reversing contactor, T100 frame, DC220V coil | Frame: T100 | Type: Non-Reversing Magnetic Contactor | Poles: 3 | Operation: DC operated | Coil: DC220V (DC220V) | AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V | AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V | AC-1 Current: 150A@200-220V / 150A@380-440V | Thermal Current Ith: 150A | Aux Contact: 2a2b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4

Need a different model, or a part not listed here? Send us your parts list →