Skip to product information
1 of 1

Mitsubishi Electric - SL-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)

Mitsubishi Electric - SL-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)

Mitsubishi Electric MS-T/N series SL-N50FK class 1 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.

Key features

  • Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one third fire temperature curve
  • Heat-resistant carrying current 56A, heat-resistant rated current 50A at AC220V, 48A at AC440V, 38A at AC550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts
  • Separate closing coil MC and tripping coil MT are specified independently; the closing coil is AC operated in AC24V, AC100V, AC200V and AC230V designations and the tripping coil may be any of the AC24V, AC100V, AC200V, AC230V, DC100V and DC200V designations
  • Mechanical and electrical durability 250,000 operations
  • Reversing type SL-2XN50FK is available, and the contactor can be switched from its own auxiliary contacts
  • Outline dimensions are the same as the standard product

Specifications

Type Class 1 heat-resistant magnetic contactor for emergency power switchboards
Frame N50
Main Contact 3a
Mechanism Mechanical latch
Operation AC operated closing coil
Heat Resistant Carrying Current 56A
Heat Resistant Rated Current AC-3 Class 50A at AC220V, 48A at AC440V, 38A at AC550V
Heat Resistant Rated Current AC-1 Class 56A at AC220V, 56A at AC440V
DC Rated Current at DC48V 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class)
DC Rated Current at DC110V 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class)
DC Rated Current at DC220V 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class)
Coil Inrush Input Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping
SL-N50FK MC-AC24V MT-AC24V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC24V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC230V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC230V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-DC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-DC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-DC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-DC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC24V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC24V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC230V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC230V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-DC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-DC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-DC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-DC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC24V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC24V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC230V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC230V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-DC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-DC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-DC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-DC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC24V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC24V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC230V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC230V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-DC100V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-DC100V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-DC200V SL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-DC200V SL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
Magnetic ContactorsMitsubishi Electric
48 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric - SL-N50FK Class 1 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 56A Carrying, 50A AC-3 at 220V)

Brand Mitsubishi Electric·Magnetic Contactors

Available part numbers (48)

SL-N50FK MC-AC24V MT-AC24V, SL-2XN50FK MC-AC24V MT-AC24V, SL-N50FK MC-AC24V MT-AC100V, SL-2XN50FK MC-AC24V MT-AC100V, SL-N50FK MC-AC24V MT-AC200V, SL-2XN50FK MC-AC24V MT-AC200V, SL-N50FK MC-AC24V MT-AC230V, SL-2XN50FK MC-AC24V MT-AC230V, SL-N50FK MC-AC24V MT-DC100V, SL-2XN50FK MC-AC24V MT-DC100V + 38 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
SL-N50FK MC-AC24V MT-AC24VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC24VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-AC230VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-AC230VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-DC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-DC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC24V MT-DC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC24V MT-DC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC24V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC24V rated 24V 50Hz, 24V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC24VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC24VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-AC230VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-AC230VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-DC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-DC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC100V MT-DC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC100V MT-DC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC100V rated 100V 50Hz, 100-110V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC24VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC24VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-AC230VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-AC230VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-DC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-DC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC200V MT-DC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC200V MT-DC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC200V rated 200V 50Hz, 200-220V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC24VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC24VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC24V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC24V rated 24V 50Hz, 24V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC100V rated 100V 50Hz, 100-110V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC200V rated 200V 50Hz, 200-220V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-AC230VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-AC230VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT AC230V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-DC100VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-DC100VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC100V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC100V rated DC100-110V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-N50FK MC-AC230V MT-DC200VSL-N50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, non-reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Non-reversing | Main Contact: 3a | Aux Contact: 2a2b | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981
SL-2XN50FK MC-AC230V MT-DC200VSL-2XN50FK class 1 heat-resistant latch contactor, MC AC230V and MT DC200V, reversing | Type: Class 1 heat-resistant magnetic contactor for emergency power switchboards | Frame: N50 | Configuration: Reversing | Main Contact: 3a | Aux Contact: 2a2b x2 | Mechanism: Mechanical latch | Operation: AC operated closing coil | Closing Coil MC: AC230V rated 220-240V 50Hz, 230-240V 60Hz | Tripping Coil MT: DC200V rated DC200-220V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at AC220V, 48A at AC440V, 38A at AC550V | Heat Resistant Rated Current AC-1 Class: 56A at AC220V, 56A at AC440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Aux Contact Rating: Carry 10A, AC-15 class 6A at 110V and 5A at 220V and 3A at 550V, AC-12 class 10A at 110V and 10A at 220V, DC-13 class 3A at DC48V and 0.6A at DC110V and 0.2A at DC220V, DC-12 class 5A at DC110V and 1A at DC220V | Coil Inrush Input: Inrush AC operated 280VA closing and 240VA tripping, DC operated 180VA closing and 230VA tripping | Operating Voltage: AC operated 140V closing and 95V tripping, DC operated 50V closing and 45V tripping | Operating Time: AC operated 11ms closing and 11ms tripping, DC operated 10ms closing and 8ms tripping | Durability: Mechanical and electrical 250,000 operations | Type Approval Number: 1MC-99040 | Heat Performance: Class 1 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one third fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981

Need a different model, or a part not listed here? Send us your parts list →