Mitsubishi Electric - SL-T100FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 105A Carrying, 100A AC-3 at 220V)

Mitsubishi Electric - SL-T100FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 105A Carrying, 100A AC-3 at 220V)

Mitsubishi Electric MS-T/N series SL-T100FN class 2 heat-resistant mechanical latch magnetic contactor for distribution boards and panelboards of dedicated emergency power receiving equipment.

Key features

  • Retains conduction and insulation function at high temperature during a fire, switching and carrying the heat-resistant rated current for 30 minutes under the one seventh fire temperature curve
  • Heat-resistant carrying current 105A, heat-resistant rated current 100A at 220V, 93A at 440V, 75A at 550V under AC-3 class, 3a main contacts with 2a2b auxiliary contacts
  • Closing coil MC and tripping coil MT are specified independently; the closing coil is AC operated and the tripping coil may be any AC or DC designation available on the frame
  • Reversing type SL-2XT100FN is available
  • Durability and outline dimensions are the same as the standard product
  • Type approval number 2MC-16178

Specifications

Type Class 2 heat-resistant mechanical latch magnetic contactor
Frame T100
Mechanism Mechanical latch
Operation AC operated closing coil
Main Contact 3a
Heat Resistant Carrying Current 105A
Heat Resistant Rated Current AC-3 Class 100A at 220V, 93A at 440V, 75A at 550V
Heat Resistant Rated Current AC-1 Class 105A at 220V, 105A at 440V
DC Rated Current at DC48V 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class)
DC Rated Current at DC110V 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class)
DC Rated Current at DC220V 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class)
Durability Same as the standard product
SL-T100FN MC-AC100V MT-AC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC300V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC300V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC400V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC400V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC500V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC500V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC12V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC12V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC24V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC24V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC48V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC48V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC125V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC125V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC300V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC300V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC400V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC400V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC500V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC500V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC12V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC12V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC24V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC24V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC48V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC48V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC125V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC125V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC300V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC300V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC400V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC400V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC500V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC500V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC12V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC12V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC24V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC24V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC48V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC48V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC125V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC125V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC300V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC300V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC400V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC400V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC500V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC500V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC12V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC12V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC24V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC24V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC48V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC48V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC125V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC125V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC300V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC300V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC400V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC400V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC500V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC500V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC12V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC12V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC24V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC24V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC48V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC48V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC100V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC100V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC125V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC125V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC200V SL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC200V SL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
Magnetic ContactorsMitsubishi Electric
110 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Mitsubishi Electric - SL-T100FN Class 2 Heat Resistant Mechanical Latch Magnetic Contactor (AC Operated Closing Coil, 105A Carrying, 100A AC-3 at 220V)

Brand Mitsubishi Electric·Magnetic Contactors

Available part numbers (110)

SL-T100FN MC-AC100V MT-AC100V, SL-2XT100FN MC-AC100V MT-AC100V, SL-T100FN MC-AC100V MT-AC200V, SL-2XT100FN MC-AC100V MT-AC200V, SL-T100FN MC-AC100V MT-AC300V, SL-2XT100FN MC-AC100V MT-AC300V, SL-T100FN MC-AC100V MT-AC400V, SL-2XT100FN MC-AC100V MT-AC400V, SL-T100FN MC-AC100V MT-AC500V, SL-2XT100FN MC-AC100V MT-AC500V + 100 more — see full table ↓

How to order

Send the Mitsubishi Electric part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
SL-T100FN MC-AC100V MT-AC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC300VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC300VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC400VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC400VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-AC500VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-AC500VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC12VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC12VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC24VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC24VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC48VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC48VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC125VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC125VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC100V MT-DC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC100V MT-DC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC300VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC300VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC400VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC400VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-AC500VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-AC500VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC12VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC12VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC24VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC24VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC48VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC48VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC125VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC125VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC200V MT-DC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC200V MT-DC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC300VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC300VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC400VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC400VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-AC500VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-AC500VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC12VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC12VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC24VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC24VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC48VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC48VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC125VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC125VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC300V MT-DC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC300V MT-DC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC300VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC300VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC400VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC400VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-AC500VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-AC500VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC12VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC12VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC24VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC24VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC48VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC48VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC125VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC125VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC400V MT-DC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC400V MT-DC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC300VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC300VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC400VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC400VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-AC500VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-AC500VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC12VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC12VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC24VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC24VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC48VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC48VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC100VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC100VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC125VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC125VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-T100FN MC-AC500V MT-DC200VSL-T100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature
SL-2XT100FN MC-AC500V MT-DC200VSL-2XT100FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T100 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 105A | Heat Resistant Rated Current AC-3 Class: 100A at 220V, 93A at 440V, 75A at 550V | Heat Resistant Rated Current AC-1 Class: 105A at 220V, 105A at 440V | DC Rated Current at DC48V: 60A 2-pole series, 90A 3-pole series (DC2 and DC4 class), 93A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC110V: 40A 2-pole series, 80A 3-pole series (DC2 and DC4 class), 80A 2-pole series, 93A 3-pole series (DC1 class) | DC Rated Current at DC220V: 30A 2-pole series, 50A 3-pole series (DC2 and DC4 class), 50A 2-pole series, 70A 3-pole series (DC1 class) | Durability: Same as the standard product | Type Approval Number: 2MC-16178 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature

Need a different model, or a part not listed here? Send us your parts list →