Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| SL-T50FN MC-AC100V MT-AC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-AC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-AC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-AC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-AC300V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-AC300V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-AC400V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-AC400V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-AC500V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-AC500V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC12V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC12V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC24V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC24V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC48V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC48V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC125V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC125V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC100V MT-DC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC100V MT-DC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC100V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC100V rated 100-127V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-AC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-AC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-AC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-AC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-AC300V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-AC300V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-AC400V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-AC400V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-AC500V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-AC500V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC12V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC12V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC24V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC24V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC48V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC48V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC125V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC125V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC200V MT-DC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC200V MT-DC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC200V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC200V rated 200-240V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-AC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-AC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-AC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-AC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-AC300V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-AC300V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-AC400V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-AC400V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-AC500V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-AC500V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC12V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC12V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC24V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC24V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC48V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC48V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC125V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC125V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC300V MT-DC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC300V MT-DC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC300V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC300V rated 260-350V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-AC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-AC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-AC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-AC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-AC300V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-AC300V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-AC400V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-AC400V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-AC500V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-AC500V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC12V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC12V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC24V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC24V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC48V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC48V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC125V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC125V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC400V MT-DC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC400V MT-DC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC400V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC400V rated 380-440V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-AC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-AC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC100V rated 100-127V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-AC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-AC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC200V rated 200-240V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-AC300V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-AC300V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC300V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC300V rated 260-350V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-AC400V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-AC400V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC400V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC400V rated 380-440V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-AC500V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-AC500V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT AC500V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: AC500V rated 460-550V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC12V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC12V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC12V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC12V rated DC12V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC24V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC24V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC24V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC24V rated DC24V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC48V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC48V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC48V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC48V rated DC48V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC100V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC100V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC100V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC100V rated DC100-110V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC125V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC125V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC125V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC125V rated DC120-125V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-T50FN MC-AC500V MT-DC200V | SL-T50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, non-reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Non-reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature | ||
| SL-2XT50FN MC-AC500V MT-DC200V | SL-2XT50FN class 2 heat-resistant latch contactor, MC AC500V and MT DC200V, reversing | Type: Class 2 heat-resistant mechanical latch magnetic contactor | Frame: T50 | Configuration: Reversing | Mechanism: Mechanical latch | Operation: AC operated closing coil | Main Contact: 3a | Aux Contact: 2a2b x2 | Closing Coil MC: AC500V rated 460-550V | Tripping Coil MT: DC200V rated DC200-220V | Coil Note: AC100V and AC200V rated coils on this frame are AC and DC common coils, 100-127V at 50/60Hz or DC100-110V for AC100V and 200-240V at 50/60Hz or DC200-220V for AC200V | Heat Resistant Carrying Current: 56A | Heat Resistant Rated Current AC-3 Class: 50A at 220V, 48A at 440V, 38A at 550V | Heat Resistant Rated Current AC-1 Class: 56A at 220V, 56A at 440V | DC Rated Current at DC48V: 25A 2-pole series, 35A 3-pole series (DC2 and DC4 class), 40A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC110V: 15A 2-pole series, 30A 3-pole series (DC2 and DC4 class), 35A 2-pole series, 50A 3-pole series (DC1 class) | DC Rated Current at DC220V: 3.5A 2-pole series, 12A 3-pole series (DC2 and DC4 class), 15A 2-pole series, 40A 3-pole series (DC1 class) | Coil Inrush Input: AC operated 120VA closing with built-in surge absorption and 250VA tripping, DC operated 120VA closing with built-in surge absorption and 200VA tripping | Operating Voltage: AC operated 130V closing and 85V tripping, DC operated 120V closing and 75V tripping | Operating Time: AC operated 23ms closing and 11ms tripping, DC operated 18ms closing and 13ms tripping | Durability: Same as the standard product | Type Approval Number: 2MC-16176 | Heat Performance: Class 2 heat resistance, switches and carries the heat-resistant rated current for 30 minutes without failure under the one seventh fire temperature curve | Certification: Certified by the Japan Electrical Manufacturers Association of Distribution Control Systems to Fire and Disaster Management Agency Notification No.10 of 1981 | Selection: For emergency power circuits keep the load current within the heat-resistant rated current and select wire sized for at least the load current divided by 0.7 at normal temperature |