| Product code | Spec | ||
|---|---|---|---|
| TH-T25SR 0.24A | TH-T25SR saturable reactor thermal relay, 0.24A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 0.24A (adjustable 0.2-0.32A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 0.35A | TH-T25SR saturable reactor thermal relay, 0.35A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 0.35A (adjustable 0.28-0.42A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 0.5A | TH-T25SR saturable reactor thermal relay, 0.5A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 0.5A (adjustable 0.4-0.6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 0.7A | TH-T25SR saturable reactor thermal relay, 0.7A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 0.7A (adjustable 0.55-0.85A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 0.9A | TH-T25SR saturable reactor thermal relay, 0.9A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 0.9A (adjustable 0.7-1.1A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 1.3A | TH-T25SR saturable reactor thermal relay, 1.3A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 1.3A (adjustable 1-1.6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 1.7A | TH-T25SR saturable reactor thermal relay, 1.7A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 1.7A (adjustable 1.4-2A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 2.1A | TH-T25SR saturable reactor thermal relay, 2.1A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 2.1A (adjustable 1.7-2.5A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 2.5A | TH-T25SR saturable reactor thermal relay, 2.5A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 2.5A (adjustable 2-3A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 3.6A | TH-T25SR saturable reactor thermal relay, 3.6A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 3.6A (adjustable 2.8-4.4A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 5A | TH-T25SR saturable reactor thermal relay, 5A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 5A (adjustable 4-6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 6.6A | TH-T25SR saturable reactor thermal relay, 6.6A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 6.6A (adjustable 5.2-8A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 9A | TH-T25SR saturable reactor thermal relay, 9A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 9A (adjustable 7-11A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 11A | TH-T25SR saturable reactor thermal relay, 11A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 11A (adjustable 9-13A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 15A | TH-T25SR saturable reactor thermal relay, 15A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 15A (adjustable 12-18A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25SR 22A | TH-T25SR saturable reactor thermal relay, 22A heater, 2-element | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 2-element | Protection: Overload | Heater: 22A (adjustable 18-26A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 0.24A | TH-T25KPSR saturable reactor thermal relay, 0.24A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 0.24A (adjustable 0.2-0.32A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 0.35A | TH-T25KPSR saturable reactor thermal relay, 0.35A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 0.35A (adjustable 0.28-0.42A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 0.5A | TH-T25KPSR saturable reactor thermal relay, 0.5A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 0.5A (adjustable 0.4-0.6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 0.7A | TH-T25KPSR saturable reactor thermal relay, 0.7A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 0.7A (adjustable 0.55-0.85A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 0.9A | TH-T25KPSR saturable reactor thermal relay, 0.9A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 0.9A (adjustable 0.7-1.1A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 1.3A | TH-T25KPSR saturable reactor thermal relay, 1.3A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 1.3A (adjustable 1-1.6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 1.7A | TH-T25KPSR saturable reactor thermal relay, 1.7A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 1.7A (adjustable 1.4-2A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 2.1A | TH-T25KPSR saturable reactor thermal relay, 2.1A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 2.1A (adjustable 1.7-2.5A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 2.5A | TH-T25KPSR saturable reactor thermal relay, 2.5A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 2.5A (adjustable 2-3A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 3.6A | TH-T25KPSR saturable reactor thermal relay, 3.6A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 3.6A (adjustable 2.8-4.4A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 5A | TH-T25KPSR saturable reactor thermal relay, 5A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 5A (adjustable 4-6A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 6.6A | TH-T25KPSR saturable reactor thermal relay, 6.6A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 6.6A (adjustable 5.2-8A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 9A | TH-T25KPSR saturable reactor thermal relay, 9A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 9A (adjustable 7-11A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 11A | TH-T25KPSR saturable reactor thermal relay, 11A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 11A (adjustable 9-13A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 15A | TH-T25KPSR saturable reactor thermal relay, 15A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 15A (adjustable 12-18A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| TH-T25KPSR 22A | TH-T25KPSR saturable reactor thermal relay, 22A heater, 3-element 2E | Frame: T25 | Type: Saturable Reactor Thermal Overload Relay | Elements: 3-element (2E) | Protection: Overload + Open-phase | Heater: 22A (adjustable 18-26A) | Mounting: For magnetic starter combination | Reset: Manual (standard) | Aux Contact: 1a1b | Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |