Key features

  • One ordering number supplies all mating connectors for the amplifier
  • Versions for amplifiers with and without built-in regenerative resistor
  • Fully-closed control sets add the EN2 external encoder connector
  • STO sets include the CN4 safety connector for wiring
  • Connectors from 3M, Molex, Phoenix Contact and Tyco Electronics

Specifications

Series SANMOTION R 3E Model
Interface Analog/pulse input type
Amplifier capacity 10 A to 600 A
Note (600 A) Amplifier unit only; PSU connector separate
Linear motor sets With hall sensor versions (p. 165)
Source Sanyo Denki SANMOTION R AC Servo Systems 100/200 VAC catalogue Ver.5.3, p. 138-141, 165
AL-00723282 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB | Use: Standard
AL-00723284 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB | Use: Standard
AL-00723286 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB | Use: Fully-closed / hall sensor
AL-00723288 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB | Use: Fully-closed / hall sensor
AL-00723290 Amplifier: 10 to 600 A | Model: Non-STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1 | Use: Standard
AL-00696037 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CNA, CNB | Use: Standard
AL-00781940 Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, EN2 | Use: Linear motor with hall sensor
AL-00723155 Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CN4 | Use: Standard
AL-00723156 Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CN4 | Use: Standard
AL-00723157 Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CN4 | Use: Fully-closed / hall sensor
AL-00723158 Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CN4 | Use: Fully-closed / hall sensor
AL-00723159 Amplifier: 10 to 600 A | Model: STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, CN4 | Use: Standard
AL-00781942 Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, EN2, CN4 | Use: Linear motor with hall sensor
AL-00946084 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CNC | Use: Standard
AL-00946086 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CNC | Use: Standard
AL-00946088 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CNC | Use: Fully-closed
AL-00946090 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CNC | Use: Fully-closed
AL-00946092 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CNA, CNB, CNC | Use: Standard
AL-00946094 Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CNB, CNC | Use: Standard
AL-00946096 Amplifier: 75 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CNC, CN4 | Use: Standard
AL-00946098 Amplifier: 75 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CNC, CN4 | Use: Standard
AL-00946100 Amplifier: 75 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CNC, CN4 | Use: Fully-closed
AL-00946102 Amplifier: 75 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CNC, CN4 | Use: Fully-closed
AL-00751448 Amplifier: 100 to 300 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA | Use: Standard
AL-00751450 Amplifier: 100 to 300 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA | Use: Fully-closed
AL-00751452 Amplifier: 100 to 300 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN4 | Use: Standard
AL-00751454 Amplifier: 100 to 300 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN4 | Use: Fully-closed
AL-00892848 Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN8 | Use: Standard
AL-00892850 Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN8 | Use: Fully-closed
AL-00892854 Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CNA, CNB | Use: Standard
AL-00892856 Amplifier: 600 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN8, CN4 | Use: Standard
AL-00892858 Amplifier: 600 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN8, CN4 | Use: Fully-closed
Servo AccessoriesSanyo Denki
32 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Sanyo Denki SANMOTION R 3E Connector Sets (Analog/Pulse Type)

Brand Sanyo Denki·Servo Accessories

Available part numbers (32)

AL-00723282, AL-00723284, AL-00723286, AL-00723288, AL-00723290, AL-00696037, AL-00781940, AL-00723155, AL-00723156, AL-00723157 + 22 more — see full table ↓

How to order

Send the Sanyo Denki part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
AL-00723282Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB | Use: Standard
AL-00723284Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB | Use: Standard
AL-00723286Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB | Use: Fully-closed / hall sensor
AL-00723288Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB | Use: Fully-closed / hall sensor
AL-00723290Amplifier: 10 to 600 A | Model: Non-STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1 | Use: Standard
AL-00696037Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CNA, CNB | Use: Standard
AL-00781940Amplifier: 10 to 50 A | Model: Non-STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, EN2 | Use: Linear motor with hall sensor
AL-00723155Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CN4 | Use: Standard
AL-00723156Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CN4 | Use: Standard
AL-00723157Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CN4 | Use: Fully-closed / hall sensor
AL-00723158Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CN4 | Use: Fully-closed / hall sensor
AL-00723159Amplifier: 10 to 600 A | Model: STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, CN4 | Use: Standard
AL-00781942Amplifier: 10 to 50 A | Model: STO | Built-in regen. resistor: No/Yes | Contents: CN1, EN1, EN2, CN4 | Use: Linear motor with hall sensor
AL-00946084Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CNC | Use: Standard
AL-00946086Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CNC | Use: Standard
AL-00946088Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CNC | Use: Fully-closed
AL-00946090Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CNC | Use: Fully-closed
AL-00946092Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: No | Contents: CNA, CNB, CNC | Use: Standard
AL-00946094Amplifier: 75 A | Model: Non-STO | Built-in regen. resistor: Yes | Contents: CNB, CNC | Use: Standard
AL-00946096Amplifier: 75 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, CNA, CNB, CNC, CN4 | Use: Standard
AL-00946098Amplifier: 75 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, CNB, CNC, CN4 | Use: Standard
AL-00946100Amplifier: 75 A | Model: STO | Built-in regen. resistor: No | Contents: CN1, EN1, EN2, CNA, CNB, CNC, CN4 | Use: Fully-closed
AL-00946102Amplifier: 75 A | Model: STO | Built-in regen. resistor: Yes | Contents: CN1, EN1, EN2, CNB, CNC, CN4 | Use: Fully-closed
AL-00751448Amplifier: 100 to 300 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA | Use: Standard
AL-00751450Amplifier: 100 to 300 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA | Use: Fully-closed
AL-00751452Amplifier: 100 to 300 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN4 | Use: Standard
AL-00751454Amplifier: 100 to 300 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN4 | Use: Fully-closed
AL-00892848Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN8 | Use: Standard
AL-00892850Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN8 | Use: Fully-closed
AL-00892854Amplifier: 600 A | Model: Non-STO | Built-in regen. resistor: - | Contents: CNA, CNB | Use: Standard
AL-00892856Amplifier: 600 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, CNA, CN8, CN4 | Use: Standard
AL-00892858Amplifier: 600 A | Model: STO | Built-in regen. resistor: - | Contents: CN1, EN1, EN2, CNA, CN8, CN4 | Use: Fully-closed