Key features

  • Hybrid topology selects economy or double conversion mode by input conditions
  • Fixed double conversion mode versions (D) for uninterrupted transfer requirements
  • 3 min backup (5 min at PF 0.7); replacement battery packs S-BPE11B... and extended battery boxes
  • Rack or vertical installation; UL 1778 / CSA / EN 62040-1 certified UJ versions
  • RS-232C and USB PC ports, remote ON/OFF; optional dry contact and LAN cards
  • Options: vertical stands STAND2UA00, floor brackets, rack rails RM030-US, air filter FL011

Specifications

Topology Hybrid
Voltage 200/208/220/230/240 V single-phase
Backup time 3 min (5 min at PF 0.7)
Battery Small VRLA lead-acid battery
Height 2U (86 mm)
Source SANUPS E11B catalog P1041B012, p. 2-15
E11B102A002AM Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B102A002AMUJ Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B102A002DM Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B102A002DMUJ Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102A012AM Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B102A012AMUJ Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B102A012DM Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B102A012DMUJ Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102B002AM Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: B | Certification: Standard
E11B102B002AMUJ Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: B | Certification: UL/CE/UKCA
E11B102B002DM Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: B | Certification: Standard
E11B102B002DMUJ Capacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: B | Certification: UL/CE/UKCA
E11B102B012AM Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: B | Certification: Standard
E11B102B012AMUJ Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: B | Certification: UL/CE/UKCA
E11B102B012DM Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: B | Certification: Standard
E11B102B012DMUJ Capacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: B | Certification: UL/CE/UKCA
E11B202A002AM Capacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B202A002AMT Capacity: 2 kVA / 1.6 kW | Input plug: Terminal block | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B202A002AMUJ Capacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B202A002DM Capacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B202A002DMT Capacity: 2 kVA / 1.6 kW | Input plug: Terminal block | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B202A002DMUJ Capacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B202A012AMUJ Capacity: 2 kVA / 1.6 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B202A012DMUJ Capacity: 2 kVA / 1.6 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B302A002AM Capacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B302A002AMT Capacity: 3 kVA / 2.4 kW | Input plug: Terminal block | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B302A002AMUJ Capacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B302A002DM Capacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B302A002DMT Capacity: 3 kVA / 2.4 kW | Input plug: Terminal block | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B302A002DMUJ Capacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B302A012AMUJ Capacity: 3 kVA / 2.4 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B302A012DMUJ Capacity: 3 kVA / 2.4 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102U002J Capacity: 1 kVA / 0.8 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.
E11B202U002J Capacity: 2 kVA / 1.6 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.
E11B302U002J Capacity: 3 kVA / 2.4 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.
UPS SystemsSanyo Denki
35 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Sanyo Denki SANUPS E11B Hybrid UPS (200 V Model)

Brand Sanyo Denki·UPS Systems

Available part numbers (35)

E11B102A002AM, E11B102A002AMUJ, E11B102A002DM, E11B102A002DMUJ, E11B102A012AM, E11B102A012AMUJ, E11B102A012DM, E11B102A012DMUJ, E11B102B002AM, E11B102B002AMUJ + 25 more — see full table ↓

How to order

Send the Sanyo Denki part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
E11B102A002AMCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B102A002AMUJCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B102A002DMCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B102A002DMUJCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102A012AMCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B102A012AMUJCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B102A012DMCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B102A012DMUJCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102B002AMCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: B | Certification: Standard
E11B102B002AMUJCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Hybrid (auto transfer) | Revision: B | Certification: UL/CE/UKCA
E11B102B002DMCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: B | Certification: Standard
E11B102B002DMUJCapacity: 1 kVA / 0.8 kW | Input plug: IEC60320-C14 | Mode: Fixed double conversion | Revision: B | Certification: UL/CE/UKCA
E11B102B012AMCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: B | Certification: Standard
E11B102B012AMUJCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: B | Certification: UL/CE/UKCA
E11B102B012DMCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: B | Certification: Standard
E11B102B012DMUJCapacity: 1 kVA / 0.8 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: B | Certification: UL/CE/UKCA
E11B202A002AMCapacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B202A002AMTCapacity: 2 kVA / 1.6 kW | Input plug: Terminal block | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B202A002AMUJCapacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B202A002DMCapacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B202A002DMTCapacity: 2 kVA / 1.6 kW | Input plug: Terminal block | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B202A002DMUJCapacity: 2 kVA / 1.6 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B202A012AMUJCapacity: 2 kVA / 1.6 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B202A012DMUJCapacity: 2 kVA / 1.6 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B302A002AMCapacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B302A002AMTCapacity: 3 kVA / 2.4 kW | Input plug: Terminal block | Mode: Hybrid (auto transfer) | Revision: A | Certification: Standard
E11B302A002AMUJCapacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B302A002DMCapacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B302A002DMTCapacity: 3 kVA / 2.4 kW | Input plug: Terminal block | Mode: Fixed double conversion | Revision: A | Certification: Standard
E11B302A002DMUJCapacity: 3 kVA / 2.4 kW | Input plug: IEC60320-C20 | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B302A012AMUJCapacity: 3 kVA / 2.4 kW | Input plug: NEMA L6-20P | Mode: Hybrid (auto transfer) | Revision: A | Certification: UL/CE/UKCA
E11B302A012DMUJCapacity: 3 kVA / 2.4 kW | Input plug: NEMA L6-20P | Mode: Fixed double conversion | Revision: A | Certification: UL/CE/UKCA
E11B102U002JCapacity: 1 kVA / 0.8 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.
E11B202U002JCapacity: 2 kVA / 1.6 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.
E11B302U002JCapacity: 3 kVA / 2.4 kW | Input plug: See order no. | Mode: Both modes | Revision: - | Certification: UL-registered no.

Need a different model, or a part not listed here? Send us your parts list →