Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| 3RV2011-0AA10 | Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0AA20 | Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0BA10 | Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0BA20 | Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0CA10 | Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0CA20 | Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0DA10 | Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0DA20 | Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0EA10 | Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0EA20 | Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0FA10 | Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0FA20 | Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0GA10 | Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0GA20 | Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0HA10 | Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0HA20 | Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0JA10 | Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0JA20 | Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0KA10 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-0KA20 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1AA10 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1AA20 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1BA10 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1BA20 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1CA10 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1CA20 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1DA10 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1DA20 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1EA10 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1EA20 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1FA10 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1FA20 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1GA10 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1GA20 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1HA10 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1HA20 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1JA10 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1JA20 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-1KA10 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-1KA20 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-4AA10 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2011-4AA20 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2011-0KA10-0BA0 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1AA10-0BA0 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1AA20-0BA0 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2011-1CA10-0BA0 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1DA10-0BA0 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1EA10-0BA0 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1FA10-0BA0 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1GA10-0BA0 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1HA10-0BA0 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1JA10-0BA0 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-1KA10-0BA0 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-4AA10-0BA0 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2011-4AA20-0BA0 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-0AA10 | Size: S0 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0BA10 | Size: S0 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0CA10 | Size: S0 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0DA10 | Size: S0 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0EA10 | Size: S0 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0FA10 | Size: S0 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0GA10 | Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0GA20 | Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-0HA10 | Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0HA20 | Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-0JA10 | Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0JA20 | Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-0KA10 | Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0KA20 | Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1AA10 | Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1AA20 | Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1BA10 | Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1BA20 | Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1CA10 | Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1CA20 | Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1DA10 | Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1DA20 | Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1EA10 | Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1EA20 | Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1FA10 | Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1FA20 | Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1GA10 | Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1GA20 | Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1HA10 | Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1HA20 | Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1JA10 | Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1JA20 | Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-1KA10 | Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-1KA20 | Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4AA10 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4AA20 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4BA10 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4BA20 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4CA10 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4CA20 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4DA10 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4DA20 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4NA10 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4NA20 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4EA10 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4EA20 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded | ||
| 3RV2021-4PA10 | Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-4FA10 | Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2021-0JA20-0BA0 | Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1AA20-0BA0 | Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1BA20-0BA0 | Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1CA20-0BA0 | Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1EA20-0BA0 | Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1GA20-0BA0 | Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1HA20-0BA0 | Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1JA20-0BA0 | Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-1KA20-0BA0 | Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-4AA20-0BA0 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-4BA10-0BA0 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2021-4CA10-0BA0 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2021-4DA10-0BA0 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2021-4DA20-0BA0 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-4NA20-0BA0 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-4EA10-0BA0 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2021-4EA20-0BA0 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded | ||
| 3RV2021-4FA10-0BA0 | Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4SA10 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4TA10 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4BA10 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4DA10 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4EA10 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4PA10 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4UA10 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4VA10 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4WA10 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4XA10 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4JA10 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4KA10 | Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4RA10 | Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2031-4DA10-0BA0 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4EA10-0BA0 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4VA10-0BA0 | Size: S2 | Setting range: 34–45 A | Motor rating: 22 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4JA10-0BA0 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2032-4SA10 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4TA10 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4BA10 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4DA10 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4EA10 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4PA10 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4UA10 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4VA10 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4WA10 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4XA10 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4JA10 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4KA10 | Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2032-4RA10 | Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2041-4FA10 | Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4HA10 | Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4JA10 | Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4KA10 | Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4RA10 | Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4YA10 | Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2041-4MA10 | Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw | ||
| 3RV2042-4FA10 | Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4HA10 | Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4JA10 | Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4KA10 | Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4RA10 | Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4YA10 | Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4MA10 | Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2011-0AA15 | Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0AA25 | Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0BA15 | Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0BA25 | Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0CA15 | Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0CA25 | Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0DA15 | Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0DA25 | Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0EA15 | Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0EA25 | Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0FA15 | Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0FA25 | Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0GA15 | Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0GA25 | Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0HA15 | Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0HA25 | Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0JA15 | Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0JA25 | Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-0KA15 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-0KA25 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1AA15 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1AA25 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1BA15 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1BA25 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1CA15 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1CA25 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1DA15 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1DA25 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1EA15 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1EA25 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1FA15 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1FA25 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1GA15 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1GA25 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1HA15 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1HA25 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1JA15 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1JA25 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1KA15 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-1KA25 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-4AA15 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2011-4AA25 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2011-1BA15-0BA0 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1CA15-0BA0 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1EA15-0BA0 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1EA25-0BA0 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Spring-loaded | ||
| 3RV2011-1FA15-0BA0 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1GA15-0BA0 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1HA15-0BA0 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-1KA15-0BA0 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2011-4AA15-0BA0 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2021-4AA15 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4AA25 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4BA15 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4BA25 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4CA15 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4CA25 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4DA15 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4DA25 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4NA15 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4NA25 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4EA15 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4EA25 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded | ||
| 3RV2021-4PA15 | Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4FA15 | Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2021-4BA15-0BA0 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2021-4EA15-0BA0 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2031-4SA15 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4TA15 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4BA15 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4DA15 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4EA15 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4PA15 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4UA15 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4VA15 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4WA15 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4XA15 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4JA15 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4KA15 | Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4RA15 | Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4SA15-0BA0 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2031-4BA15-0BA0 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2031-4EA15-0BA0 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2031-4VA15-0BA0 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw | ||
| 3RV2032-4SA15 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 10 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4TA15 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4BA15 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4DA15 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4EA15 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4PA15 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4UA15 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4VA15 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4WA15 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4XA15 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4JA15 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4KA15 | Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2032-4RA15 | Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw | ||
| 3RV2041-4FA15 | Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4HA15 | Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4JA15 | Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4KA15 | Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4RA15 | Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4YA15 | Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2041-4MA15 | Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4SB10 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4TB10 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4BB10 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4DB10 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4EB10 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4PB10 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4UB10 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4VB10 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4WB10 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4XB10 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4JB10 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw | ||
| 3RV2031-4EB10-0BA0 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4PB10-0BA0 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2031-4UB10-0BA0 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw | ||
| 3RV2042-4FB10 | Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4HB10 | Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4JB10 | Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4KB10 | Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4RB10 | Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4YB10 | Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2042-4MB10 | Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw | ||
| 3RV2031-4SB15 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4TB15 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4BB15 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4DB15 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4EB15 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4PB15 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4UB15 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4VB15 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4WB15 | Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4XB15 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw | ||
| 3RV2031-4JB15 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw |
Need a different model, or a part not listed here? Send us your parts list →