Skip to product information
1 of 1

Siemens SIRIUS 3RV20 Motor Starter Protectors (S00–S3, Class 10/20)

Siemens SIRIUS 3RV20 Motor Starter Protectors (S00–S3, Class 10/20)

SIRIUS 3RV20 motor starter protectors/circuit breakers protect three-phase motors against overload and short circuit in sizes S00 to S3 up to 100 A.

Key features

  • Adjustable inverse-time delayed thermal overload release with phase-failure sensitivity
  • Instantaneous electronic short-circuit release, breaking capacity up to 100 kA at 400 V AC
  • Trip class 10 (S00–S3) and class 20 (S2/S3) versions
  • Versions without auxiliary switch or with integrated transverse auxiliary switch 1 NO + 1 NC
  • Screw or spring-loaded terminals (S00/S0); -0BA0 versions for operation down to -50 °C
  • Sizes S2/S3 also with increased switching capacity (3RV2032, 3RV2042)

Specifications

Product line SIRIUS 3RV2
Function Motor protection
Rated voltage Up to 690 V AC
Standard IEC 60947-2, IEC 60947-4-1
Brand Siemens
Catalog section IC 10 ch. 7 Protection equipment
Category Motor Starter Protectors
Poles 3
Rated frequency 50/60 Hz
Mounting DIN rail or screw fixing
Source Siemens Catalog IC 10 · 2026, p. 7/25-7/32
3RV2011-0AA10 Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0AA20 Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0BA10 Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0BA20 Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0CA10 Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0CA20 Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0DA10 Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0DA20 Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0EA10 Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0EA20 Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0FA10 Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0FA20 Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0GA10 Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0GA20 Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0HA10 Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0HA20 Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0JA10 Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0JA20 Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0KA10 Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0KA20 Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1AA10 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1AA20 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1BA10 Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1BA20 Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1CA10 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1CA20 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1DA10 Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1DA20 Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1EA10 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1EA20 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1FA10 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1FA20 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1GA10 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1GA20 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1HA10 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1HA20 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1JA10 Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1JA20 Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1KA10 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1KA20 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-4AA10 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-4AA20 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0KA10-0BA0 Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1AA10-0BA0 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1AA20-0BA0 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2011-1CA10-0BA0 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1DA10-0BA0 Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1EA10-0BA0 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1FA10-0BA0 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1GA10-0BA0 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1HA10-0BA0 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1JA10-0BA0 Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1KA10-0BA0 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-4AA10-0BA0 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-4AA20-0BA0 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-0AA10 Size: S0 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0BA10 Size: S0 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0CA10 Size: S0 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0DA10 Size: S0 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0EA10 Size: S0 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0FA10 Size: S0 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0GA10 Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0GA20 Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0HA10 Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0HA20 Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0JA10 Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0JA20 Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0KA10 Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0KA20 Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1AA10 Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1AA20 Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1BA10 Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1BA20 Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1CA10 Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1CA20 Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1DA10 Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1DA20 Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1EA10 Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1EA20 Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1FA10 Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1FA20 Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1GA10 Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1GA20 Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1HA10 Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1HA20 Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1JA10 Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1JA20 Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1KA10 Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1KA20 Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4AA10 Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4AA20 Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4BA10 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4BA20 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4CA10 Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4CA20 Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4DA10 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4DA20 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4NA10 Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4NA20 Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4EA10 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4EA20 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4PA10 Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4FA10 Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0JA20-0BA0 Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1AA20-0BA0 Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1BA20-0BA0 Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1CA20-0BA0 Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1EA20-0BA0 Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1GA20-0BA0 Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1HA20-0BA0 Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1JA20-0BA0 Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1KA20-0BA0 Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4AA20-0BA0 Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4BA10-0BA0 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4CA10-0BA0 Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4DA10-0BA0 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4DA20-0BA0 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4NA20-0BA0 Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4EA10-0BA0 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4EA20-0BA0 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4FA10-0BA0 Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4SA10 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4TA10 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4BA10 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4DA10 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4EA10 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4PA10 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4UA10 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4VA10 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4WA10 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4XA10 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4JA10 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4KA10 Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4RA10 Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4DA10-0BA0 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4EA10-0BA0 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4VA10-0BA0 Size: S2 | Setting range: 34–45 A | Motor rating: 22 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4JA10-0BA0 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2032-4SA10 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4TA10 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4BA10 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4DA10 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4EA10 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4PA10 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4UA10 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4VA10 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4WA10 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4XA10 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4JA10 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4KA10 Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4RA10 Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2041-4FA10 Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4HA10 Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4JA10 Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4KA10 Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4RA10 Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4YA10 Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4MA10 Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2042-4FA10 Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4HA10 Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4JA10 Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4KA10 Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4RA10 Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4YA10 Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4MA10 Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2011-0AA15 Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0AA25 Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0BA15 Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0BA25 Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0CA15 Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0CA25 Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0DA15 Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0DA25 Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0EA15 Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0EA25 Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0FA15 Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0FA25 Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0GA15 Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0GA25 Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0HA15 Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0HA25 Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0JA15 Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0JA25 Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0KA15 Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0KA25 Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1AA15 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1AA25 Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1BA15 Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1BA25 Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1CA15 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1CA25 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1DA15 Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1DA25 Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1EA15 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1EA25 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1FA15 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1FA25 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1GA15 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1GA25 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1HA15 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1HA25 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1JA15 Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1JA25 Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1KA15 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1KA25 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-4AA15 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-4AA25 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1BA15-0BA0 Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1CA15-0BA0 Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1EA15-0BA0 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1EA25-0BA0 Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Spring-loaded
3RV2011-1FA15-0BA0 Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1GA15-0BA0 Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1HA15-0BA0 Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1KA15-0BA0 Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-4AA15-0BA0 Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2021-4AA15 Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4AA25 Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4BA15 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4BA25 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4CA15 Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4CA25 Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4DA15 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4DA25 Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4NA15 Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4NA25 Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4EA15 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4EA25 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4PA15 Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4FA15 Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4BA15-0BA0 Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2021-4EA15-0BA0 Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4SA15 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4TA15 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4BA15 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4DA15 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4EA15 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4PA15 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4UA15 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4VA15 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4WA15 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4XA15 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4JA15 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4KA15 Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4RA15 Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4SA15-0BA0 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4BA15-0BA0 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4EA15-0BA0 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4VA15-0BA0 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2032-4SA15 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 10 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4TA15 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4BA15 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4DA15 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4EA15 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4PA15 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4UA15 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4VA15 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4WA15 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4XA15 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4JA15 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4KA15 Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4RA15 Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2041-4FA15 Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4HA15 Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4JA15 Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4KA15 Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4RA15 Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4YA15 Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4MA15 Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4SB10 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4TB10 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4BB10 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4DB10 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4EB10 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4PB10 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4UB10 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4VB10 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4WB10 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4XB10 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4JB10 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4EB10-0BA0 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4PB10-0BA0 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4UB10-0BA0 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2042-4FB10 Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4HB10 Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4JB10 Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4KB10 Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4RB10 Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4YB10 Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4MB10 Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2031-4SB15 Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4TB15 Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4BB15 Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4DB15 Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4EB15 Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4PB15 Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4UB15 Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4VB15 Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4WB15 Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4XB15 Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4JB15 Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
Motor Starter ProtectorsSiemens
301 product codes available in this family
Sourced direct from KoreaExport-ready supplyCompetitive pricing

Need a different model, or a part not listed here? Send us your parts list →

Siemens SIRIUS 3RV20 Motor Starter Protectors (S00–S3, Class 10/20)

Brand Siemens·Motor Starter Protectors

Available part numbers (301)

3RV2011-0AA10, 3RV2011-0AA20, 3RV2011-0BA10, 3RV2011-0BA20, 3RV2011-0CA10, 3RV2011-0CA20, 3RV2011-0DA10, 3RV2011-0DA20, 3RV2011-0EA10, 3RV2011-0EA20 + 291 more — see full table ↓

How to order

Send the Siemens part numbers and quantities through our RFQ form or to info@prosourcemro.com. We confirm price, availability and lead time within 1 business day — no account needed.

RFQ List 0 →
View full details
Product codes & specifications
0 selected
RFQ List (0)
Product codeSpec
3RV2011-0AA10Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0AA20Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0BA10Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0BA20Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0CA10Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0CA20Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0DA10Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0DA20Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0EA10Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0EA20Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0FA10Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0FA20Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0GA10Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0GA20Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0HA10Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0HA20Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0JA10Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0JA20Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0KA10Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-0KA20Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1AA10Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1AA20Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1BA10Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1BA20Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1CA10Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1CA20Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1DA10Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1DA20Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1EA10Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1EA20Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1FA10Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1FA20Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1GA10Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1GA20Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1HA10Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1HA20Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1JA10Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1JA20Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-1KA10Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-1KA20Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-4AA10Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2011-4AA20Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2011-0KA10-0BA0Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1AA10-0BA0Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1AA20-0BA0Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2011-1CA10-0BA0Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1DA10-0BA0Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1EA10-0BA0Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1FA10-0BA0Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1GA10-0BA0Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1HA10-0BA0Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1JA10-0BA0Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-1KA10-0BA0Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-4AA10-0BA0Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2011-4AA20-0BA0Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-0AA10Size: S0 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0BA10Size: S0 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0CA10Size: S0 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0DA10Size: S0 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0EA10Size: S0 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0FA10Size: S0 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0GA10Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0GA20Size: S0 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0HA10Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0HA20Size: S0 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0JA10Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0JA20Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-0KA10Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0KA20Size: S0 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1AA10Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1AA20Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1BA10Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1BA20Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1CA10Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1CA20Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1DA10Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1DA20Size: S0 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1EA10Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1EA20Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1FA10Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1FA20Size: S0 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1GA10Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1GA20Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1HA10Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1HA20Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1JA10Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1JA20Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-1KA10Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-1KA20Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4AA10Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4AA20Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4BA10Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4BA20Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4CA10Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4CA20Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4DA10Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4DA20Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4NA10Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4NA20Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4EA10Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4EA20Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch | Connection: Spring-loaded
3RV2021-4PA10Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-4FA10Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2021-0JA20-0BA0Size: S0 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1AA20-0BA0Size: S0 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1BA20-0BA0Size: S0 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1CA20-0BA0Size: S0 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1EA20-0BA0Size: S0 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1GA20-0BA0Size: S0 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1HA20-0BA0Size: S0 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1JA20-0BA0Size: S0 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-1KA20-0BA0Size: S0 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4AA20-0BA0Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4BA10-0BA0Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4CA10-0BA0Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4DA10-0BA0Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4DA20-0BA0Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4NA20-0BA0Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4EA10-0BA0Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2021-4EA20-0BA0Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Spring-loaded
3RV2021-4FA10-0BA0Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4SA10Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4TA10Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4BA10Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4DA10Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4EA10Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4PA10Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4UA10Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4VA10Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4WA10Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4XA10Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4JA10Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4KA10Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4RA10Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2031-4DA10-0BA0Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4EA10-0BA0Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4VA10-0BA0Size: S2 | Setting range: 34–45 A | Motor rating: 22 kW | Icu 400 V: 50 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4JA10-0BA0Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch, -50 °C version | Connection: Screw
3RV2032-4SA10Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4TA10Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4BA10Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4DA10Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4EA10Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4PA10Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4UA10Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4VA10Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4WA10Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4XA10Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4JA10Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4KA10Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2032-4RA10Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2041-4FA10Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4HA10Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4JA10Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4KA10Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4RA10Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4YA10Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2041-4MA10Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, no aux. switch | Connection: Screw
3RV2042-4FA10Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4HA10Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4JA10Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4KA10Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4RA10Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4YA10Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2042-4MA10Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 10, no aux. switch, high Icu | Connection: Screw
3RV2011-0AA15Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0AA25Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0BA15Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0BA25Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0CA15Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0CA25Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0DA15Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0DA25Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0EA15Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0EA25Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0FA15Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0FA25Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0GA15Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0GA25Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0HA15Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0HA25Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0JA15Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0JA25Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-0KA15Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-0KA25Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1AA15Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1AA25Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1BA15Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1BA25Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1CA15Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1CA25Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1DA15Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1DA25Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1EA15Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1EA25Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1FA15Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1FA25Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1GA15Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1GA25Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1HA15Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1HA25Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1JA15Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1JA25Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1KA15Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-1KA25Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-4AA15Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2011-4AA25Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2011-1BA15-0BA0Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1CA15-0BA0Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1EA15-0BA0Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1EA25-0BA0Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Spring-loaded
3RV2011-1FA15-0BA0Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1GA15-0BA0Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1HA15-0BA0Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-1KA15-0BA0Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2011-4AA15-0BA0Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2021-4AA15Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4AA25Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4BA15Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4BA25Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4CA15Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4CA25Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4DA15Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4DA25Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4NA15Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4NA25Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4EA15Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4EA25Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC | Connection: Spring-loaded
3RV2021-4PA15Size: S0 | Setting range: 30–36 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4FA15Size: S0 | Setting range: 34–40 A | Motor rating: 18.5 kW | Icu 400 V: 20 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2021-4BA15-0BA0Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2021-4EA15-0BA0Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4SA15Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4TA15Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4BA15Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4DA15Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4EA15Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4PA15Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4UA15Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4VA15Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4WA15Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4XA15Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4JA15Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4KA15Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4RA15Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4SA15-0BA0Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4BA15-0BA0Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4EA15-0BA0Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2031-4VA15-0BA0Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC, -50 °C version | Connection: Screw
3RV2032-4SA15Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 10 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4TA15Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4BA15Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4DA15Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4EA15Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4PA15Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4UA15Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4VA15Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4WA15Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4XA15Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4JA15Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4KA15Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2032-4RA15Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 10, 1 NO + 1 NC, high Icu | Connection: Screw
3RV2041-4FA15Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4HA15Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4JA15Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4KA15Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4RA15Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4YA15Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2041-4MA15Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 65 kA | Version: Class 10, 1 NO + 1 NC | Connection: Screw
3RV2031-4SB10Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4TB10Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4BB10Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4DB10Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4EB10Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4PB10Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4UB10Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4VB10Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4WB10Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4XB10Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4JB10Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch | Connection: Screw
3RV2031-4EB10-0BA0Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4PB10-0BA0Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2031-4UB10-0BA0Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, no aux. switch, -50 °C version | Connection: Screw
3RV2042-4FB10Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4HB10Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4JB10Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4KB10Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4RB10Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4YB10Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2042-4MB10Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Class 20, no aux. switch, high Icu | Connection: Screw
3RV2031-4SB15Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4TB15Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4BB15Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4DB15Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4EB15Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4PB15Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4UB15Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4VB15Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4WB15Size: S2 | Setting range: 42–52 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4XB15Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw
3RV2031-4JB15Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Class 20, 1 NO + 1 NC | Connection: Screw

Need a different model, or a part not listed here? Send us your parts list →