Product codes & specifications
| Product code | Spec | ||
|---|---|---|---|
| 3RV2111-0AA10 | Size: S00 | Setting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0BA10 | Size: S00 | Setting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0CA10 | Size: S00 | Setting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0DA10 | Size: S00 | Setting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0EA10 | Size: S00 | Setting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0FA10 | Size: S00 | Setting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0GA10 | Size: S00 | Setting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0HA10 | Size: S00 | Setting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0JA10 | Size: S00 | Setting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-0KA10 | Size: S00 | Setting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1AA10 | Size: S00 | Setting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1BA10 | Size: S00 | Setting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1CA10 | Size: S00 | Setting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1DA10 | Size: S00 | Setting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1EA10 | Size: S00 | Setting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1FA10 | Size: S00 | Setting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1GA10 | Size: S00 | Setting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1HA10 | Size: S00 | Setting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1JA10 | Size: S00 | Setting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-1KA10 | Size: S00 | Setting range: 9–12.5 A | Motor rating: 5.5 kW | Icu 400 V: 100 kA | Version: Standard | ||
| 3RV2111-4AA10 | Size: S00 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4AA10 | Size: S0 | Setting range: 10–16 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4BA10 | Size: S0 | Setting range: 13–20 A | Motor rating: 7.5 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4CA10 | Size: S0 | Setting range: 16–22 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4DA10 | Size: S0 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4NA10 | Size: S0 | Setting range: 23–28 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2121-4EA10 | Size: S0 | Setting range: 27–32 A | Motor rating: 15 kW | Icu 400 V: 55 kA | Version: Standard | ||
| 3RV2131-4SA10 | Size: S2 | Setting range: 9.5–14 A | Motor rating: 5.5 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4TA10 | Size: S2 | Setting range: 12–17 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4BA10 | Size: S2 | Setting range: 14–20 A | Motor rating: 7.5 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4DA10 | Size: S2 | Setting range: 18–25 A | Motor rating: 11 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4EA10 | Size: S2 | Setting range: 22–32 A | Motor rating: 15 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4PA10 | Size: S2 | Setting range: 28–36 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4UA10 | Size: S2 | Setting range: 32–40 A | Motor rating: 18.5 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4VA10 | Size: S2 | Setting range: 35–45 A | Motor rating: 22 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4WA10 | Size: S2 | Setting range: 42–52 A | Motor rating: 32 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4XA10 | Size: S2 | Setting range: 49–59 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4JA10 | Size: S2 | Setting range: 54–65 A | Motor rating: 30 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4KA10 | Size: S2 | Setting range: 62–73 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2131-4RA10 | Size: S2 | Setting range: 70–80 A | Motor rating: 37 kW | Icu 400 V: 65 kA | Version: Standard | ||
| 3RV2142-4FA10 | Size: S3 | Setting range: 28–40 A | Motor rating: 18.5 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4HA10 | Size: S3 | Setting range: 36–50 A | Motor rating: 22 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4JA10 | Size: S3 | Setting range: 45–63 A | Motor rating: 30 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4KA10 | Size: S3 | Setting range: 57–75 A | Motor rating: 37 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4RA10 | Size: S3 | Setting range: 65–84 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4YA10 | Size: S3 | Setting range: 75–93 A | Motor rating: 45 kW | Icu 400 V: 100 kA | Version: Increased switching capacity | ||
| 3RV2142-4MA10 | Size: S3 | Setting range: 80–100 A | Motor rating: 45, 55 kW | Icu 400 V: 100 kA | Version: Increased switching capacity |