Metasol MMS-63S Manual Motor Starter — Mid Range (10~26A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (63AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Mid range for motors 2.2~11kW (5.5kW @ 220V / 11kW @ 440V). Frame: 63AF, width 55mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.

10 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MMS-63S/10A Metasol MMS-63S 10A, Standard terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/10A O-RING TERMINAL Metasol MMS-63S 10A, O-Ring Terminal terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/13A Metasol MMS-63S 13A, Standard terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/13A O-RING TERMINAL Metasol MMS-63S 13A, O-Ring Terminal terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/17A Metasol MMS-63S 17A, Standard terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/17A O-RING TERMINAL Metasol MMS-63S 17A, O-Ring Terminal terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/22A Metasol MMS-63S 22A, Standard terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/22A O-RING TERMINAL Metasol MMS-63S 22A, O-Ring Terminal terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/26A Metasol MMS-63S 26A, Standard terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC
MMS-63S/26A O-RING TERMINAL Metasol MMS-63S 26A, O-Ring Terminal terminal, Standard (Mid Range) LS ELECTRIC Frame: 63AF | Capacity Band: Mid Range (10~26A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 55mm | Weight: ~1000g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC