[LS ELECTRIC] — TS100L-ETS Susol MCCB (Limited (Current limiting), 150kA @ 415V, ETS 40~100A)

[LS ELECTRIC] — TS100L-ETS Susol MCCB (Limited (Current limiting), 150kA @ 415V, ETS 40~100A)

Family ID: LSE-TS100L-ETS

LS ELECTRIC Susol MCCB TS100L-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.

12 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
TS100L-ETS100-40A-2P Susol MCCB TS100L-ETS — 40A ETS100, 2-pole LS ELECTRIC Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-40A-3P Susol MCCB TS100L-ETS — 40A ETS100, 3-pole LS ELECTRIC Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-40A-4PL Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (L) LS ELECTRIC Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-40A-4PR Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (R) LS ELECTRIC Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-80A-2P Susol MCCB TS100L-ETS — 80A ETS100, 2-pole LS ELECTRIC Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-80A-3P Susol MCCB TS100L-ETS — 80A ETS100, 3-pole LS ELECTRIC Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-80A-4PL Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (L) LS ELECTRIC Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-80A-4PR Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (R) LS ELECTRIC Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-100A-2P Susol MCCB TS100L-ETS — 100A ETS100, 2-pole LS ELECTRIC Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-100A-3P Susol MCCB TS100L-ETS — 100A ETS100, 3-pole LS ELECTRIC Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-100A-4PL Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (L) LS ELECTRIC Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV
TS100L-ETS100-100A-4PR Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (R) LS ELECTRIC Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV