Molded Case Circuit Breakers
LS ELECTRIC Susol MCCB TD100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100H-FTU100-16A-2P | Susol MCCB TD100H-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-16A-3P | Susol MCCB TD100H-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-16A-4PL | Susol MCCB TD100H-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-2P | Susol MCCB TD100H-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-3P | Susol MCCB TD100H-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-4PL | Susol MCCB TD100H-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-2P | Susol MCCB TD100H-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-3P | Susol MCCB TD100H-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-4PL | Susol MCCB TD100H-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-2P | Susol MCCB TD100H-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-3P | Susol MCCB TD100H-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-4PL | Susol MCCB TD100H-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-2P | Susol MCCB TD100H-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-3P | Susol MCCB TD100H-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-4PL | Susol MCCB TD100H-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-2P | Susol MCCB TD100H-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-3P | Susol MCCB TD100H-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-4PL | Susol MCCB TD100H-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-2P | Susol MCCB TD100H-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-3P | Susol MCCB TD100H-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-4PL | Susol MCCB TD100H-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-2P | Susol MCCB TD100H-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-3P | Susol MCCB TD100H-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-4PL | Susol MCCB TD100H-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-2P | Susol MCCB TD100H-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-3P | Susol MCCB TD100H-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-4PL | Susol MCCB TD100H-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100L-FTU100-16A-2P | Susol MCCB TD100L-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-16A-3P | Susol MCCB TD100L-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-16A-4PL | Susol MCCB TD100L-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-2P | Susol MCCB TD100L-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-3P | Susol MCCB TD100L-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-4PL | Susol MCCB TD100L-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-2P | Susol MCCB TD100L-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-3P | Susol MCCB TD100L-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-4PL | Susol MCCB TD100L-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-2P | Susol MCCB TD100L-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-3P | Susol MCCB TD100L-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-4PL | Susol MCCB TD100L-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-2P | Susol MCCB TD100L-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-3P | Susol MCCB TD100L-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-4PL | Susol MCCB TD100L-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-2P | Susol MCCB TD100L-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-3P | Susol MCCB TD100L-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-4PL | Susol MCCB TD100L-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-2P | Susol MCCB TD100L-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-3P | Susol MCCB TD100L-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-4PL | Susol MCCB TD100L-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-2P | Susol MCCB TD100L-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-3P | Susol MCCB TD100L-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-4PL | Susol MCCB TD100L-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-2P | Susol MCCB TD100L-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-3P | Susol MCCB TD100L-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-4PL | Susol MCCB TD100L-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100N-FTU100-16A-2P | Susol MCCB TD100N-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-16A-3P | Susol MCCB TD100N-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-16A-4PL | Susol MCCB TD100N-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-2P | Susol MCCB TD100N-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-3P | Susol MCCB TD100N-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-4PL | Susol MCCB TD100N-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-2P | Susol MCCB TD100N-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-3P | Susol MCCB TD100N-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-4PL | Susol MCCB TD100N-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-2P | Susol MCCB TD100N-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-3P | Susol MCCB TD100N-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-4PL | Susol MCCB TD100N-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-2P | Susol MCCB TD100N-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-3P | Susol MCCB TD100N-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-4PL | Susol MCCB TD100N-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-2P | Susol MCCB TD100N-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-3P | Susol MCCB TD100N-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-4PL | Susol MCCB TD100N-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-2P | Susol MCCB TD100N-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-3P | Susol MCCB TD100N-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-4PL | Susol MCCB TD100N-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-2P | Susol MCCB TD100N-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-3P | Susol MCCB TD100N-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-4PL | Susol MCCB TD100N-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-2P | Susol MCCB TD100N-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-3P | Susol MCCB TD100N-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-4PL | Susol MCCB TD100N-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160H-FTU160-100A-2P | Susol MCCB TD160H-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-100A-3P | Susol MCCB TD160H-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-100A-4PL | Susol MCCB TD160H-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-2P | Susol MCCB TD160H-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-3P | Susol MCCB TD160H-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-4PL | Susol MCCB TD160H-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-2P | Susol MCCB TD160H-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-3P | Susol MCCB TD160H-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-4PL | Susol MCCB TD160H-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160L-FTU160-100A-2P | Susol MCCB TD160L-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-100A-3P | Susol MCCB TD160L-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-100A-4PL | Susol MCCB TD160L-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-2P | Susol MCCB TD160L-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-3P | Susol MCCB TD160L-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-4PL | Susol MCCB TD160L-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-2P | Susol MCCB TD160L-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-3P | Susol MCCB TD160L-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-4PL | Susol MCCB TD160L-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160N-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160N-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160N-FTU160-100A-2P | Susol MCCB TD160N-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-100A-3P | Susol MCCB TD160N-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-100A-4PL | Susol MCCB TD160N-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-2P | Susol MCCB TD160N-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-3P | Susol MCCB TD160N-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-4PL | Susol MCCB TD160N-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-2P | Susol MCCB TD160N-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-3P | Susol MCCB TD160N-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-4PL | Susol MCCB TD160N-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100H-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100H-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100H-ETS100-40A-2P | Susol MCCB TS100H-ETS — 40A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-3P | Susol MCCB TS100H-ETS — 40A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-4PL | Susol MCCB TS100H-ETS — 40A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-4PR | Susol MCCB TS100H-ETS — 40A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-2P | Susol MCCB TS100H-ETS — 80A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-3P | Susol MCCB TS100H-ETS — 80A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-4PL | Susol MCCB TS100H-ETS — 80A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-4PR | Susol MCCB TS100H-ETS — 80A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-2P | Susol MCCB TS100H-ETS — 100A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-3P | Susol MCCB TS100H-ETS — 100A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-4PL | Susol MCCB TS100H-ETS — 100A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-4PR | Susol MCCB TS100H-ETS — 100A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100H-FTU100-40A-2P | Susol MCCB TS100H-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-3P | Susol MCCB TS100H-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-4PL | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-4PR | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-2P | Susol MCCB TS100H-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-3P | Susol MCCB TS100H-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-4PL | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-4PR | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-2P | Susol MCCB TS100H-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-3P | Susol MCCB TS100H-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-4PL | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-4PR | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-2P | Susol MCCB TS100H-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-3P | Susol MCCB TS100H-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-4PL | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-4PR | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-2P | Susol MCCB TS100H-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-3P | Susol MCCB TS100H-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-4PL | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-4PR | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS100Hi family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS100Hi family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100Hi-ETSi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100L-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100L-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100L-ETS100-40A-2P | Susol MCCB TS100L-ETS — 40A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-3P | Susol MCCB TS100L-ETS — 40A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-4PL | Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-4PR | Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-2P | Susol MCCB TS100L-ETS — 80A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-3P | Susol MCCB TS100L-ETS — 80A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-4PL | Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-4PR | Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-2P | Susol MCCB TS100L-ETS — 100A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-3P | Susol MCCB TS100L-ETS — 100A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-4PL | Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-4PR | Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100L-FTU100-40A-2P | Susol MCCB TS100L-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-40A-3P | Susol MCCB TS100L-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-40A-4PL | Susol MCCB TS100L-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-40A-4PR | Susol MCCB TS100L-FTU — 40A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-50A-2P | Susol MCCB TS100L-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-50A-3P | Susol MCCB TS100L-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-50A-4PL | Susol MCCB TS100L-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-50A-4PR | Susol MCCB TS100L-FTU — 50A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-63A-2P | Susol MCCB TS100L-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-63A-3P | Susol MCCB TS100L-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-63A-4PL | Susol MCCB TS100L-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-63A-4PR | Susol MCCB TS100L-FTU — 63A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-80A-2P | Susol MCCB TS100L-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-80A-3P | Susol MCCB TS100L-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-80A-4PL | Susol MCCB TS100L-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-80A-4PR | Susol MCCB TS100L-FTU — 80A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-100A-2P | Susol MCCB TS100L-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-100A-3P | Susol MCCB TS100L-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-100A-4PL | Susol MCCB TS100L-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-FTU100-100A-4PR | Susol MCCB TS100L-FTU — 100A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS100Li family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 150kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS100Li family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 150kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100Li-ETSi-40A-3P | Susol Smart MCCB TS100Li — 40A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETSi-40A-4PL | Susol Smart MCCB TS100Li — 40A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETSi-40A-4PR | Susol Smart MCCB TS100Li — 40A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-40A-3P | Susol Smart MCCB TS100Li — 40A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-40A-4PL | Susol Smart MCCB TS100Li — 40A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-40A-4PR | Susol Smart MCCB TS100Li — 40A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-40A-3P | Susol Smart MCCB TS100Li — 40A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-40A-4PL | Susol Smart MCCB TS100Li — 40A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-40A-4PR | Susol Smart MCCB TS100Li — 40A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-40A-3P | Susol Smart MCCB TS100Li — 40A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-40A-4PL | Susol Smart MCCB TS100Li — 40A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-40A-4PR | Susol Smart MCCB TS100Li — 40A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETSi-100A-3P | Susol Smart MCCB TS100Li — 100A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETSi-100A-4PL | Susol Smart MCCB TS100Li — 100A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETSi-100A-4PR | Susol Smart MCCB TS100Li — 100A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-100A-3P | Susol Smart MCCB TS100Li — 100A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-100A-4PL | Susol Smart MCCB TS100Li — 100A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETMi-100A-4PR | Susol Smart MCCB TS100Li — 100A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-100A-3P | Susol Smart MCCB TS100Li — 100A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-100A-4PL | Susol Smart MCCB TS100Li — 100A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETHi-100A-4PR | Susol Smart MCCB TS100Li — 100A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-100A-3P | Susol Smart MCCB TS100Li — 100A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-100A-4PL | Susol Smart MCCB TS100Li — 100A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Li-ETLi-100A-4PR | Susol Smart MCCB TS100Li — 100A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100N-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100N-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100N-ETS100-40A-2P | Susol MCCB TS100N-ETS — 40A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-40A-3P | Susol MCCB TS100N-ETS — 40A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-40A-4PL | Susol MCCB TS100N-ETS — 40A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-40A-4PR | Susol MCCB TS100N-ETS — 40A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-80A-2P | Susol MCCB TS100N-ETS — 80A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-80A-3P | Susol MCCB TS100N-ETS — 80A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-80A-4PL | Susol MCCB TS100N-ETS — 80A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-80A-4PR | Susol MCCB TS100N-ETS — 80A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-100A-2P | Susol MCCB TS100N-ETS — 100A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-100A-3P | Susol MCCB TS100N-ETS — 100A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-100A-4PL | Susol MCCB TS100N-ETS — 100A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-ETS100-100A-4PR | Susol MCCB TS100N-ETS — 100A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100N-FTU100-40A-2P | Susol MCCB TS100N-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-40A-3P | Susol MCCB TS100N-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-40A-4PL | Susol MCCB TS100N-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-40A-4PR | Susol MCCB TS100N-FTU — 40A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-50A-2P | Susol MCCB TS100N-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-50A-3P | Susol MCCB TS100N-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-50A-4PL | Susol MCCB TS100N-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-50A-4PR | Susol MCCB TS100N-FTU — 50A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-63A-2P | Susol MCCB TS100N-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-63A-3P | Susol MCCB TS100N-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-63A-4PL | Susol MCCB TS100N-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-63A-4PR | Susol MCCB TS100N-FTU — 63A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-80A-2P | Susol MCCB TS100N-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-80A-3P | Susol MCCB TS100N-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-80A-4PL | Susol MCCB TS100N-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-80A-4PR | Susol MCCB TS100N-FTU — 80A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-100A-2P | Susol MCCB TS100N-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-100A-3P | Susol MCCB TS100N-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-100A-4PL | Susol MCCB TS100N-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100N-FTU100-100A-4PR | Susol MCCB TS100N-FTU — 100A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS100Ni family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 50kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS100Ni family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 50kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100Ni-ETSi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETSi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETSi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-40A-3P | Susol Smart MCCB TS100Ni — 40A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-40A-4PL | Susol Smart MCCB TS100Ni — 40A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-40A-4PR | Susol Smart MCCB TS100Ni — 40A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETSi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETSi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETSi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETMi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETHi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-100A-3P | Susol Smart MCCB TS100Ni — 100A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-100A-4PL | Susol Smart MCCB TS100Ni — 100A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Ni-ETLi-100A-4PR | Susol Smart MCCB TS100Ni — 100A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS160H-ETS family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS160H-ETS family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS160H-ETS160-40A-2P | Susol MCCB TS160H-ETS — 40A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-40A-3P | Susol MCCB TS160H-ETS — 40A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-40A-4PL | Susol MCCB TS160H-ETS — 40A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-40A-4PR | Susol MCCB TS160H-ETS — 40A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-80A-2P | Susol MCCB TS160H-ETS — 80A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-80A-3P | Susol MCCB TS160H-ETS — 80A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-80A-4PL | Susol MCCB TS160H-ETS — 80A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-80A-4PR | Susol MCCB TS160H-ETS — 80A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-100A-2P | Susol MCCB TS160H-ETS — 100A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-100A-3P | Susol MCCB TS160H-ETS — 100A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-100A-4PL | Susol MCCB TS160H-ETS — 100A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-100A-4PR | Susol MCCB TS160H-ETS — 100A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-160A-2P | Susol MCCB TS160H-ETS — 160A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-160A-3P | Susol MCCB TS160H-ETS — 160A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-160A-4PL | Susol MCCB TS160H-ETS — 160A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-ETS160-160A-4PR | Susol MCCB TS160H-ETS — 160A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS160H-FTU160-100A-2P | Susol MCCB TS160H-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-100A-3P | Susol MCCB TS160H-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-100A-4PL | Susol MCCB TS160H-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-100A-4PR | Susol MCCB TS160H-FTU — 100A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-125A-2P | Susol MCCB TS160H-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-125A-3P | Susol MCCB TS160H-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-125A-4PL | Susol MCCB TS160H-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-125A-4PR | Susol MCCB TS160H-FTU — 125A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-160A-2P | Susol MCCB TS160H-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-160A-3P | Susol MCCB TS160H-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-160A-4PL | Susol MCCB TS160H-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160H-FTU160-160A-4PR | Susol MCCB TS160H-FTU — 160A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS160Hi family. Frame: 160AF | Rated current: 40A, 100A, 160A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 36 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS160Hi family. Frame: 160AF | Rated current: 40A, 100A, 160A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 36 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS160Hi-ETSi-40A-3P | Susol Smart MCCB TS160Hi — 40A ETSi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-40A-4PL | Susol Smart MCCB TS160Hi — 40A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-40A-4PR | Susol Smart MCCB TS160Hi — 40A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-40A-3P | Susol Smart MCCB TS160Hi — 40A ETMi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-40A-4PL | Susol Smart MCCB TS160Hi — 40A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-40A-4PR | Susol Smart MCCB TS160Hi — 40A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-40A-3P | Susol Smart MCCB TS160Hi — 40A ETHi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-40A-4PL | Susol Smart MCCB TS160Hi — 40A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-40A-4PR | Susol Smart MCCB TS160Hi — 40A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-40A-3P | Susol Smart MCCB TS160Hi — 40A ETLi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-40A-4PL | Susol Smart MCCB TS160Hi — 40A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-40A-4PR | Susol Smart MCCB TS160Hi — 40A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-100A-3P | Susol Smart MCCB TS160Hi — 100A ETSi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-100A-4PL | Susol Smart MCCB TS160Hi — 100A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-100A-4PR | Susol Smart MCCB TS160Hi — 100A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-100A-3P | Susol Smart MCCB TS160Hi — 100A ETMi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-100A-4PL | Susol Smart MCCB TS160Hi — 100A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-100A-4PR | Susol Smart MCCB TS160Hi — 100A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-100A-3P | Susol Smart MCCB TS160Hi — 100A ETHi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-100A-4PL | Susol Smart MCCB TS160Hi — 100A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-100A-4PR | Susol Smart MCCB TS160Hi — 100A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-100A-3P | Susol Smart MCCB TS160Hi — 100A ETLi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-100A-4PL | Susol Smart MCCB TS160Hi — 100A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-100A-4PR | Susol Smart MCCB TS160Hi — 100A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-160A-3P | Susol Smart MCCB TS160Hi — 160A ETSi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-160A-4PL | Susol Smart MCCB TS160Hi — 160A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETSi-160A-4PR | Susol Smart MCCB TS160Hi — 160A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-160A-3P | Susol Smart MCCB TS160Hi — 160A ETMi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-160A-4PL | Susol Smart MCCB TS160Hi — 160A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETMi-160A-4PR | Susol Smart MCCB TS160Hi — 160A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-160A-3P | Susol Smart MCCB TS160Hi — 160A ETHi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-160A-4PL | Susol Smart MCCB TS160Hi — 160A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETHi-160A-4PR | Susol Smart MCCB TS160Hi — 160A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-160A-3P | Susol Smart MCCB TS160Hi — 160A ETLi, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-160A-4PL | Susol Smart MCCB TS160Hi — 160A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160Hi-ETLi-160A-4PR | Susol Smart MCCB TS160Hi — 160A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS160L-ETS family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS160L-ETS family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS160L-ETS160-40A-2P | Susol MCCB TS160L-ETS — 40A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-40A-3P | Susol MCCB TS160L-ETS — 40A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-40A-4PL | Susol MCCB TS160L-ETS — 40A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-40A-4PR | Susol MCCB TS160L-ETS — 40A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-80A-2P | Susol MCCB TS160L-ETS — 80A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-80A-3P | Susol MCCB TS160L-ETS — 80A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-80A-4PL | Susol MCCB TS160L-ETS — 80A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-80A-4PR | Susol MCCB TS160L-ETS — 80A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-100A-2P | Susol MCCB TS160L-ETS — 100A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-100A-3P | Susol MCCB TS160L-ETS — 100A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-100A-4PL | Susol MCCB TS160L-ETS — 100A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-100A-4PR | Susol MCCB TS160L-ETS — 100A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-160A-2P | Susol MCCB TS160L-ETS — 160A ETS160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-160A-3P | Susol MCCB TS160L-ETS — 160A ETS160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-160A-4PL | Susol MCCB TS160L-ETS — 160A ETS160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-ETS160-160A-4PR | Susol MCCB TS160L-ETS — 160A ETS160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS160 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS160L-FTU160-100A-2P | Susol MCCB TS160L-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-100A-3P | Susol MCCB TS160L-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-100A-4PL | Susol MCCB TS160L-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-100A-4PR | Susol MCCB TS160L-FTU — 100A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-125A-2P | Susol MCCB TS160L-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-125A-3P | Susol MCCB TS160L-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-125A-4PL | Susol MCCB TS160L-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-125A-4PR | Susol MCCB TS160L-FTU — 125A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-160A-2P | Susol MCCB TS160L-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-160A-3P | Susol MCCB TS160L-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-160A-4PL | Susol MCCB TS160L-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS160L-FTU160-160A-4PR | Susol MCCB TS160L-FTU — 160A FTU160, 4-pole (R) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |