Molded Case Circuit Breakers
LS ELECTRIC
[LS ELECTRIC] — UTV250-N-ATU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 100~250A, IEC60947-2)
Family ID: LSE-UTV250-N-ATU-IEC
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
8 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| UTV250-N-ATU-100A-3P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-100A-4P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-150A-3P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-150A-4P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-200A-3P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-200A-4P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-250A-3P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-ATU-250A-4P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |