LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
12 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| UTV250-N-FMU-60A-3P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-60A-4P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-80A-3P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-80A-4P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-100A-3P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-100A-4P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-150A-3P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-150A-4P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-200A-3P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-200A-4P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-250A-3P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | ||
| UTV250-N-FMU-250A-4P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |