Magnetic Starters
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — MS-T/N Series MS-2xN125KP Enclosed Reversing Magnetic Starter (125A AC-3, N125 Frame, TH-N120(TA)KP 3-Element Thermal)
Family ID: MEL-MSE-KP-2XN125
Mitsubishi Electric MS-T/N series N125-frame reversing enclosed-type magnetic starter MS-2xN125KP with TH-N120(TA)KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching. Auxiliary contact option units cannot be added to enclosed types.
35 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MS-2xN125KP 42A AC24V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC48V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC100V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC200V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC300V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC400V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 42A AC500V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC24V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC48V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC100V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC200V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC300V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC400V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 54A AC500V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC24V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC48V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC100V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC200V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC300V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC400V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 67A AC500V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC24V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC48V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC100V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC200V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC300V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC400V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 82A AC500V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC24V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC48V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC100V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC200V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC300V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC400V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MS-2xN125KP 105A AC500V | MS-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |