Magnetic Starters
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — MS-T/N Series MSOD-N400 Magnetic Starter (400A AC-3, N400 Frame, TH-N400RH Thermal)
Family ID: MEL-MSTR-D-N400
Mitsubishi Electric MS-T/N series N400-frame non-reversing open-type magnetic starter MSOD-N400: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
48 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MSOD-N400 105A DC12V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC24V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC48V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC100V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC110V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC125V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC200V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 105A DC220V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC12V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC24V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC48V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC100V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC110V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC125V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC200V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 125A DC220V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC12V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC24V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC48V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC100V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC110V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC125V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC200V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 150A DC220V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC12V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC24V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC48V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC100V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC110V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC125V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC200V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 180A DC220V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC12V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC24V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC48V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC100V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC110V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC125V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC200V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 250A DC220V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC12V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC24V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC48V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC100V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC110V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC125V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC200V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N400 330A DC220V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |