[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xT10 Reversing Magnetic Starter (11A AC-3, T10 Frame, TH-T18 Thermal)
Magnetic Starters MITSUBISHI ELECTRIC

[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xT10 Reversing Magnetic Starter (11A AC-3, T10 Frame, TH-T18 Thermal)

Family ID: MEL-MSTR-2XT10

Mitsubishi Electric MS-T/N series T10-frame reversing open-type magnetic starter MSO-2xT10: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.2kW / 11A (AC-3) at 200-220V and 2.7kW / 7A at 380-440V, Ith 20A. Heater designations 0.12A to 9A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.

105 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSO-2xT10 0.12A AC24V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC48V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC100V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC200V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC300V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC400V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.12A AC500V MSO-2xT10 reversing starter, T10 frame, 0.12A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC24V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC48V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC100V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC200V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC300V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC400V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.17A AC500V MSO-2xT10 reversing starter, T10 frame, 0.17A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC24V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC48V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC100V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC200V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC300V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC400V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.24A AC500V MSO-2xT10 reversing starter, T10 frame, 0.24A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC24V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC48V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC100V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC200V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC300V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC400V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.35A AC500V MSO-2xT10 reversing starter, T10 frame, 0.35A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC24V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC48V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC100V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC200V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC300V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC400V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.5A AC500V MSO-2xT10 reversing starter, T10 frame, 0.5A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC24V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC48V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC100V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC200V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC300V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC400V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.7A AC500V MSO-2xT10 reversing starter, T10 frame, 0.7A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC24V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC48V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC100V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC200V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC300V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC400V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 0.9A AC500V MSO-2xT10 reversing starter, T10 frame, 0.9A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC24V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC48V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC100V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC200V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC300V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC400V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.3A AC500V MSO-2xT10 reversing starter, T10 frame, 1.3A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC24V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC48V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC100V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC200V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC300V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC400V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 1.7A AC500V MSO-2xT10 reversing starter, T10 frame, 1.7A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC24V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC48V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC100V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC200V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC300V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC400V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.1A AC500V MSO-2xT10 reversing starter, T10 frame, 2.1A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC24V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC48V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC100V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC200V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC300V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC400V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 2.5A AC500V MSO-2xT10 reversing starter, T10 frame, 2.5A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC24V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC48V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC100V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC200V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC300V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC400V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 3.6A AC500V MSO-2xT10 reversing starter, T10 frame, 3.6A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC24V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC48V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC100V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC200V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC300V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC400V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 5A AC500V MSO-2xT10 reversing starter, T10 frame, 5A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC24V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC48V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC100V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC200V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC300V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC400V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 6.6A AC500V MSO-2xT10 reversing starter, T10 frame, 6.6A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC24V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC24V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC48V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC48V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC100V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC100V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC200V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC200V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC300V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC300V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC400V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC400V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT10 9A AC500V MSO-2xT10 reversing starter, T10 frame, 9A heater, AC500V coil Mitsubishi Electric Frame: T10 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4