Mitsubishi Electric MS-T/N series T25-frame non-reversing open-type magnetic starter MSO-T25: AC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 5.5kW / 26A (AC-3) at 200-220V and 11kW / 25A at 380-440V, Ith 32A. Heater designations 0.24A to 22A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
112 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MSO-T25 0.24A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.24A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.35A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.5A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.7A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 0.9A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC24V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC48V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC100V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC200V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC300V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC400V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.3A AC500V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC24V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC48V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC100V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC200V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC300V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC400V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 1.7A AC500V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC24V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC48V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC100V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC200V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC300V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC400V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.1A AC500V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC24V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC48V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC100V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC200V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC300V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC400V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 2.5A AC500V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC24V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC48V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC100V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC200V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC300V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC400V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 3.6A AC500V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC24V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC48V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC100V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC200V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC300V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC400V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 5A AC500V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC24V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC48V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC100V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC200V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC300V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC400V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 6.6A AC500V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC24V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC48V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC100V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC200V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC300V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC400V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 9A AC500V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC24V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC48V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC100V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC200V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC300V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC400V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 11A AC500V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC24V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC48V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC100V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC200V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC300V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC400V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 15A AC500V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC24V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC48V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC100V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC200V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC300V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC400V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSO-T25 22A AC500V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |