Mitsubishi Electric MS-T/N series N150-frame non-reversing open-type magnetic starter MSO-N150: AC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.

42 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSO-N150 42A AC24V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC48V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC100V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC200V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC300V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC400V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 42A AC500V MSO-N150 non-reversing starter, N150 frame, 42A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC24V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC48V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC100V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC200V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC300V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC400V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 54A AC500V MSO-N150 non-reversing starter, N150 frame, 54A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC24V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC48V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC100V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC200V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC300V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC400V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 67A AC500V MSO-N150 non-reversing starter, N150 frame, 67A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC24V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC48V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC100V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC200V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC300V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC400V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 82A AC500V MSO-N150 non-reversing starter, N150 frame, 82A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC24V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC48V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC100V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC200V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC300V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC400V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 105A AC500V MSO-N150 non-reversing starter, N150 frame, 105A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC24V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC24V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC48V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC48V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC100V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC100V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC200V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC200V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC300V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC300V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC400V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC400V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-N150 125A AC500V MSO-N150 non-reversing starter, N150 frame, 125A heater, AC500V coil Mitsubishi Electric Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4