Magnetic Starters
MITSUBISHI ELECTRIC
[MITSUBISHI ELECTRIC] — MS-T/N Series MSOD-N220 Magnetic Starter (220A AC-3, N220 Frame, TH-N220RH Thermal)
Family ID: MEL-MSTR-D-N220
Mitsubishi Electric MS-T/N series N220-frame non-reversing open-type magnetic starter MSOD-N220: DC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
40 product codes available in this family
Product Codes & Specifications
| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| MSOD-N220 82A DC12V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC24V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC48V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC100V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC110V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC125V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC200V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 82A DC220V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC12V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC24V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC48V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC100V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC110V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC125V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC200V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 105A DC220V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC12V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC24V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC48V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC100V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC110V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC125V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC200V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 125A DC220V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC12V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC24V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC48V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC100V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC110V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC125V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC200V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 150A DC220V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC12V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC24V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC48V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC100V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC110V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC125V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC200V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | ||
| MSOD-N220 180A DC220V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |