[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xT100 Reversing Magnetic Starter (100A AC-3, T100 Frame, TH-T65/T100 Thermal)
Magnetic Starters MITSUBISHI ELECTRIC

[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-2xT100 Reversing Magnetic Starter (100A AC-3, T100 Frame, TH-T65/T100 Thermal)

Family ID: MEL-MSTR-2XT100

Mitsubishi Electric MS-T/N series T100-frame reversing open-type magnetic starter MSO-2xT100: AC-operated contactor combined with TH-T65/T100 2-element thermal overload relay (manual reset standard). Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.

56 product codes available in this family

Product Codes & Specifications

Product Code Description Brand Spec
MSO-2xT100 15A AC24V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC48V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC100V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC200V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC300V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC400V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 15A AC500V MSO-2xT100 reversing starter, T100 frame, 15A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC24V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC48V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC100V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC200V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC300V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC400V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 22A AC500V MSO-2xT100 reversing starter, T100 frame, 22A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC24V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC48V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC100V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC200V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC300V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC400V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 29A AC500V MSO-2xT100 reversing starter, T100 frame, 29A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC24V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC48V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC100V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC200V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC300V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC400V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 35A AC500V MSO-2xT100 reversing starter, T100 frame, 35A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC24V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC48V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC100V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC200V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC300V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC400V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 42A AC500V MSO-2xT100 reversing starter, T100 frame, 42A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC24V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC48V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC100V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC200V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC300V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC400V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 54A AC500V MSO-2xT100 reversing starter, T100 frame, 54A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC24V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC48V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC100V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC200V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC300V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC400V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 67A AC500V MSO-2xT100 reversing starter, T100 frame, 67A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC24V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC24V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC48V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC48V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC100V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC100V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC200V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC200V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC300V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC300V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC400V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC400V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4
MSO-2xT100 82A AC500V MSO-2xT100 reversing starter, T100 frame, 82A heater, AC500V coil Mitsubishi Electric Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4