| Product Code | Description | Brand | Spec | ||
|---|---|---|---|---|---|
| E2EW-QX1R5B18-M1 | E2EW-Q M8 1.5mm PNP NO M12 conn | OMRON | Size: M8 | Sensing Distance: 1.5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Output: PNP | Operation Mode: NO | Connection: M12 Connector | Note: NPN not available for M8 size | ||
| E2EW-QX2B112 2M | E2EW-Q M12 2mm PNP NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX2B112 5M | E2EW-Q M12 2mm PNP NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX2B112-M1TJ 0.3M | E2EW-Q M12 2mm PNP NO SC 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX2B312 2M | E2EW-Q M12 2mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX2B312 5M | E2EW-Q M12 2mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX2B312-M1TJ 0.3M | E2EW-Q M12 2mm PNP NO+NC SC 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX2C112 2M | E2EW-Q M12 2mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX2C112 5M | E2EW-Q M12 2mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX2C112-M1TJ 0.3M | E2EW-Q M12 2mm NPN NO SC 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX2C312 2M | E2EW-Q M12 2mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX2C312 5M | E2EW-Q M12 2mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX2C312-M1TJ 0.3M | E2EW-Q M12 2mm NPN NO+NC SC 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX5B118 2M | E2EW-Q M18 5mm PNP NO 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX5B118 5M | E2EW-Q M18 5mm PNP NO 5m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX5B118-M1TJ 0.3M | E2EW-Q M18 5mm PNP NO SC 0.3m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX5B318 2M | E2EW-Q M18 5mm PNP NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX5B318 5M | E2EW-Q M18 5mm PNP NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX5B318-M1TJ 0.3M | E2EW-Q M18 5mm PNP NO+NC SC 0.3m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX5C118 2M | E2EW-Q M18 5mm NPN NO 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX5C118 5M | E2EW-Q M18 5mm NPN NO 5m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX5C118-M1TJ 0.3M | E2EW-Q M18 5mm NPN NO SC 0.3m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX5C318 2M | E2EW-Q M18 5mm NPN NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX5C318 5M | E2EW-Q M18 5mm NPN NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX5C318-M1TJ 0.3M | E2EW-Q M18 5mm NPN NO+NC SC 0.3m | OMRON | Size: M18 | Sensing Distance: 5 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX10B130 2M | E2EW-Q M30 10mm PNP NO 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX10B130 5M | E2EW-Q M30 10mm PNP NO 5m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX10B130-M1TJ 0.3M | E2EW-Q M30 10mm PNP NO SC 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX10B330 2M | E2EW-Q M30 10mm PNP NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX10B330 5M | E2EW-Q M30 10mm PNP NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX10B330-M1TJ 0.3M | E2EW-Q M30 10mm PNP NO+NC SC 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX10C130 2M | E2EW-Q M30 10mm NPN NO 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | ||
| E2EW-QX10C130 5M | E2EW-Q M30 10mm NPN NO 5m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | ||
| E2EW-QX10C130-M1TJ 0.3M | E2EW-Q M30 10mm NPN NO SC 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | ||
| E2EW-QX10C330 2M | E2EW-Q M30 10mm NPN NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | ||
| E2EW-QX10C330 5M | E2EW-Q M30 10mm NPN NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | ||
| E2EW-QX10C330-M1TJ 0.3M | E2EW-Q M30 10mm NPN NO+NC SC 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Grade: BASIC Single Spatter-resistant (1×) | Wire: DC 3-wire | IO-Link: IO-Link not supported for BASIC model | Note: NC models available: replace '1' with '2' in model number | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m |